The bicipital groove as a landmark for reconstruction of complex proximal humeral fractures with hybrid double plate osteosynthesis.

نویسندگان

  • Jan Theopold
  • Bastian Marquaß
  • Johannes Fakler
  • Hanno Steinke
  • Christoph Josten
  • Pierre Hepp
چکیده

BACKGROUND Complex proximal humerus fractures with metaphyseal comminution remain challenging regarding reduction and stability. In most fracture patterns the hard bone of the bicipital groove remains intact. In this case series, we describe a novel technique of hybrid double plate osteosynthesis of complex proximal humerus fractures with metaphyseal comminution. METHODS In randomly chosen shoulder specimens and synthetic bones, pilot studies for evaluation of the feasibility of the technique were performed. Between 4/2010 and 1/2012 10 patients underwent hybrid double plate osteosynthesis. Seven patients (4 male, 3 female, mean age was 50 years (range 27-73)) were available for retrospective analysis. Based on plain radiographs (anterior-posterior and axial view), the fractures were classified according to the Orthopaedic Trauma Association classification (OTA) and by descriptive means (head-split variant (HS), diaphyseal extension or comminution (DE)). RESULTS Follow-up radiographs demonstrated complete fracture healing in six patients and one incomplete avascular necrosis. None of the patients sustained loss of reduction. Three patients where reoperated. The medium, not adapted, Constant score was 80 Points (58-94). Patients subjective satisfaction was graded mean 3 (range: 0-6) in the visual analog scoring system (VAS). CONCLUSION The technique of hybrid double plate osteosynthesis using the bicipital groove as anatomic landmark may re-establish shoulder function after complex proximal humerus fractures in two dimensions. Firstly the anatomy is restored due to a proper reduction based on intraoperative landmarks. Secondly additional support by the second plate may provide a higher stability in complex fractures with metaphyseal comminution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repositioning of the humeral tuberosities can be guided by pectoralis major insertion

In complex proximal humerus fractures, positioning of the tuberosities can be a challenge. This study demonstrates the constant angle between the pectoralis major (PM) and the medial lip of the bicipital groove (BG) on the horizontal axial plane. This angle can be used to determine the rotation, as well as the positioning of the tuberosities, when planning a hemiarthroplasty or a reconstruction...

متن کامل

Minimally invasive plate osteosynthesis using a helical plate for metadiaphyseal complex fractures of the proximal humerus.

Minimally invasive plate osteosynthesis (MIPO) has been used for humeral shaft fractures, but concerns exist about soft tissue injuries. The purpose of this study was to report the surgical technique and clinical outcomes of MIPO using a helical plate for metadiaphyseal complex humeral shaft fractures. Twelve patients with acute displacement involving proximal and middle third humeral shaft fra...

متن کامل

Operative Treatment of Proximal Humeral Fracturedislocations Through an Anterolateral Deltoid Split Approach

Background: Proximal humeral fracture-dislocations (PHFD) are a special entity in proximal humeral fracturetreatment. The aim of this study is to present our minimally invasive plate osteosynthesis (MIPO) technique throughan anterolateral deltoid split approach. In addition, we performed a retrospective cohort study analyzing the patientreported functional outcome and complica...

متن کامل

Morphometric & Morphological Study of Bicipital Groove in North Indian Population

The bicipital groove is an important landmark for humeral head placement in fractures of the proximal humerus. It contains the long head of the biceps brachii muscle, its synovial sheath and an ascending branch of the anterior circumflex humeral artery. The BG & LBT are intimately related. The shape of the BG has a great impact on the tendency for the LBT to be dislocated or subluxated. A shall...

متن کامل

Osteosynthesis of Proximal Humeral End Fractures with Fixed-angle Plate and Locking Screws: Technique and Results

UNLABELLED Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. METHOD Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC surgery

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016