Hls New Bpm Calibrating and Error Analysis*
نویسنده
چکیده
A precise calibrating system for newly adopted beam position monitors (BPM) of upgraded injection system in NSRL phase II project is described. The fitting error of the electric field is presented. Using the calibrating system and the method which has a system error about ±15μm and the precision of 1μm, we have completed the calibration and checking of the quality to the developed equipment. Due to the beam pipe is fixed vertically and move the antenna to simulate beam orbit deviation, as well as we adopt the RF CW simulating the beam and not the previously 5MHz CW, and the results show fine precision and better reliability.
منابع مشابه
Health Literacy Impact on National Healthcare Utilization and Expenditure
Background Health literacy presents an enormous challenge in the delivery of effective healthcare and quality outcomes. We evaluated the impact of low health literacy (LHL) on healthcare utilization and healthcare expenditure. Methods Database analysis used Medical Expenditure Panel Survey (MEPS) from 2005-2008 which provides nationally representative estimates of healthcare utilization and e...
متن کاملError Analysis of the Through Reflect Line Method for Calibrating Microwave Measurements By
GHOSH, RAHUL. Error analysis of Through Reflect Line method for calibrating microwave measurements. (Under the direction of Professor Michael B. Steer) Uncertainty in transmission line based calibration techniques for microwave measurements are studied with the aim of identifying the optimum calibration conditions. Variation in the determined error parameters under certain conditions in Through...
متن کاملMathematical Morphology in the HLS Colour Space
The HLS colour space is widely used in image analysis as it is physically intuitive. As the hue component of this space is defined on the unit circle, standard greyscale image analysis operators, specifically morphological operators, are not applicable to it. A variation of the standard morphological operators which require the choice of an origin are discussed. In addition, some lexicographica...
متن کاملPERFORMANCE ANALYSIS AND VERIFICATION FOR HIGH-LEVEL SYNTHESIS By JOHN A. CURRERI A DISSERTATION PRESENTED TO THE GRADUATE SCHOOL OF THE UNIVERSITY OF FLORIDA IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF DOCTOR OF PHILOSOPHY UNIVERSITY OF FLORIDA
of Dissertation Presented to the Graduate School of the University of Florida in Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy PERFORMANCE ANALYSIS AND VERIFICATION FOR HIGH-LEVEL SYNTHESIS By John A. Curreri May 2011 Chair: Alan D. George and Greg Stitt Major: Electrical and Computer Engineering High-Level Synthesis (HLS) for Field-Programmable Gate Arrays (FPG...
متن کاملThe Effects of Human New Pressor Protein and Coagulation Factor XIIa on Blood Pressure and Heart Rate in Bilaterally Nephrectomized Rats
Background: New Pressor Protein (NPP) is a human plasma enzyme structurally related to b–fragment of activated factor XІІ (β-FXIIa). The objective of the present study was to investigate the effects of NPP and β-FXIIa on systolic blood pressure and heart rate in bilateral nephrectomized rats. Methods: Forty male Wistar rats (250-300 g) were sham-operated or bilaterally nephrectomized under anes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2001