Effect of Inspiratory Time and Lung Compliance on Flow Bias Generated During Manual Hyperinflation: A Bench Study.

نویسندگان

  • Bradley G Bennett
  • Peter Thomas
  • George Ntoumenopoulos
چکیده

BACKGROUND Manual hyperinflation can be used to assist mucus clearance in intubated patients. The technique's effectiveness to move mucus is underpinned by its ability to generate flow bias in the direction of expiration, and this must exceed specific thresholds. It is unclear whether the inspiratory times commonly used by physiotherapists generate sufficient expiratory flow bias based on previously published thresholds and whether factors such as lung compliance affect this. METHODS In a series of laboratory experiments, we applied manual hyperinflation to a bench model to examine the role of 3 target inspiratory times and 2 lung compliance settings on 3 measures of expiratory flow bias. RESULTS Longer inspiratory times and lower lung compliances were associated with improvements in all measures of expiratory flow bias. In normal compliance lungs, achievement of the expiratory flow bias thresholds were (1) never achieved with an inspiratory time of 1 s, (2) rarely achieved with an inspiratory time of 2 s, and (3) commonly achieved with an inspiratory time of 3 s. In lower compliance lungs, achievement of the expiratory flow bias thresholds was (1) rarely achieved with an inspiratory time of 1 s, (2) sometimes achieved with an inspiratory time of 2 s, and (3) nearly always achieved with an inspiratory time of 3 s. Peak inspiratory pressures exceeded 40 cm H2O in normal compliance lungs with inspiratory times of 1 s and in lower compliance lungs with inspiratory times of 1 and 2 s. CONCLUSIONS Inspiratory times of at least 3 s with normal compliance lungs and at least 2 s with lower compliance lungs appear necessary to achieve expiratory flow bias thresholds during manual hyperinflation. Inspiratory times shorter than this may lead to excessive peak inspiratory pressures. Verification of these findings in relation to the movement of mucus should be examined in further bench or animal models and/or human clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic effects of manual hyperinflation in critically ill mechanically ventilated patients.

SUBJECT OBJECTIVE To assess the hemodynamic effects of manual lung hyperinflation in mechanically ventilated patients and to measure the different inspiratory pressures and tidal volumes generated by different operators. DESIGN Measurements of aortic blood flow (by esophageal Doppler ultrasonography), systemic blood pressure, tidal volumes (by respirometry), and inspiratory pressures in the v...

متن کامل

Effects of manual hyperinflation, clinical practice versus expert recommendation, on displacement of mucus simulant: A laboratory study

INTRODUCTION Manual hyperinflation (MH), a maneuver applied in mechanically ventilated patients to facilitate secretion removal, has large variation in its performance. Effectiveness of MH is usually evaluated by its capacity to generate an expiratory flow bias. The aim of this study was to compare the effects of MH-and its resulting flow bias-applied according to clinical practice versus accor...

متن کامل

The effect on expiratory flow rate of maintaining bag compression during manual hyperinflation.

Operator performance during the expiratory phase of manual hyperinflation appears to vary between physiotherapists for Mapleson-B or C circuits. Some physiotherapists release the valve but maintain compression of the bag, whereas others release both the valve and the bag. The effect of this difference on peak expiratory flow rate (PEFR) has not been reported. The aim of this study was to docume...

متن کامل

A new ventilator for monitoring lung mechanics in small animals.

Researchers investigating the genetic component of various disease states rely increasingly on murine models. We have developed a ventilator to simplify respiratory research in small animals down to murine size. The new ventilator provides constant-flow inflation and tidal volume delivery independent of respiratory parameter changes. The inclusion of end-inspiratory and end-expiratory pauses si...

متن کامل

Does experience influence the performance of neonatal and pediatric manual hyperinflation?

BACKGROUND Manual hyperinflation (MH) is used to improve mucociliary clearance and alveolar expansion in mechanically ventilated patients. Despite the popularity of MH, studies with adults have shown considerable variability in the results from its use. This study assessed if professional training on the application of MH influences its performance. METHODS An experimental study was conducte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 60 10  شماره 

صفحات  -

تاریخ انتشار 2015