Characterization of a static thermal-gradient CCN counter

نویسندگان

  • G. P. Frank
  • U. Dusek
  • M. O. Andreae
چکیده

The static (parallel-plate thermal-gradient) diffusion chamber (SDC) was one of the first instruments designed to measure cloud condensation nuclei (CCN) concentrations as a function of supersaturation. It has probably also been the most widely used type of CCN counter. This paper describes the detailed experimental characterization of 5 a SDC CCN counter, including calibration with respect to supersaturation and particle number concentration. In addition, we investigated the proposed effect of lowered su-persaturation because of water vapor depletion with increasing particle concentration. The results obtained gives a larger understanding why and in which way it is necessary to calibrate the SDC CCN counter. The calibration method is described in detail 10 as well. The method can, in parts, be used for calibrations also for other types of CCN counters. We conclude the following: 1) it is important to experimentally calibrate SDC CCN counters with respect to supersaturation, and not only base the supersaturation on the theoretical description of the instrument; 2) the number concentration calibration needs 15 to be performed as a function of supersaturation, also for SDC CCN counter using the photographic technique; and 3) we observed no evidence that water vapor depletion lowered the supersaturation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical Note : Characterization of a static thermal - gradient CCN counter

The static (parallel-plate thermal-gradient) diffusion chamber (SDC) was one of the first instruments designed to measure cloud condensation nuclei (CCN) concentrations as a function of supersaturation. It has probably also been the most widely used type of CCN counter. This paper describes the detailed experimental characterization of a SDC CCN counter, including calibration with respect to su...

متن کامل

Mapping the Operation of the DMT Continuous Flow CCN Counter

This work thoroughly analyzes a new commercial instrument for measuring Cloud Condensation Nuclei (CCN), the Droplet Measurement Technologies Cylindrical Continuous-Flow Streamwise Thermal Gradient CCN Chamber (CFSTGC). This instrument can measure CCN concentrations at supersaturations from 0.06% to 3% (potentially up to 6%), at a 1 Hz sampling rate that is sufficient for airborne operation. Ou...

متن کامل

Scanning Flow CCN Analysis - A Method for Fast Measurements of CCN Spectra

The Continuous-Flow Streamwise Thermal-Gradient Cloud Condensation Nuclei Counter is a commercially-available instrument that is widely used for laboratory and field measurements of cloud condensation nuclei (CCN). Typically, the instrument is operated at a constant flow rate, and supersaturation is adjusted by changing the column streamwise temperature difference, which is slow and may introdu...

متن کامل

A Continuous - Flow Streamwise Thermal - Gradient CCN Chamber for Atmospheric 4 Measurements 5 Short Title : Continuous - Flow Streamwise CCN Chamber

24 We have addressed the need for improved measurements of cloud condensation nuclei 25 (CCN) by developing a continuous-flow instrument that provides in situ measurements of CCN. 26 The design presented in this paper can operate between 0.1% and 3% supersaturation, at 27 sampling rates sufficient for airborne operation. The design constitutes a cylindrical continuous28 flow thermal-gradient di...

متن کامل

Towards the Determination of Joint Volatility- Hygroscopicity Distributions: Development and Response Characterization for Single-Component Aerosol

This work presents the development and characterization of a thermodenuder for the study and interpretation of aerosol volatility. Thermodenuder measurements are further combined with a Continuous-Flow Streamwise Thermal Gradient CCN Counter (CFSTGC) to obtain the corresponding aerosol hygroscopicity. The thermodenuder response function is characterized with monodisperse aerosol of variable vol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005