Absolute density measurement of SD radicals in a supersonic jet at the quantum-noise-limit.

نویسندگان

  • Arin Mizouri
  • L Z Deng
  • Jack S Eardley
  • N Hendrik Nahler
  • Eckart Wrede
  • David Carty
چکیده

The absolute density of SD radicals in a supersonic jet has been measured down to (1.1 ± 0.1) × 10(5) cm(-3) in a modestly specified apparatus that uses a cross-correlated combination of cavity ring-down and laser-induced fluorescence detection. Such a density corresponds to 215 ± 21 molecules in the probe volume at any given time. The minimum detectable absorption coefficient was quantum-noise-limited and measured to be (7.9 ± 0.6) × 10(-11) cm(-1), in 200 s of acquisition time, corresponding to a noise-equivalent absorption sensitivity for the apparatus of (1.6 ± 0.1) × 10(-9) cm(-1) Hz(-1/2).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modulation Response and Relative Intensity Noise Spectra in Quantum Cascade Lasers

Static properties, relatively intensity noise and intensity modulation response in quantum cascade lasers (QCLs) studied theoretically in this paper. The present rate equations model consists of three equations for the electrons density in the conduction band and one equation for photons density in cavity length. Two equations were derived to calculate the noise and modulation response. Calcula...

متن کامل

بررسی دقت توموگرافی خطی در تعیین محل حفره بینی و سینوس ماگزیلاری1

Background and Aim: Accurate measurement of bone height and width is essential prior to dental implant placement. The method of surgery as well as, the type and size of implants are determined according to dimensions of the residual bone. The purpose of this study was to evaluate the accuracy of linear tomography in localization of the floor of nasal fossa and maxillary sinus, and to determine ...

متن کامل

Quantitative optical tomographic imaging of a supersonic jet.

Two-dimensional quantitative images of the density of chlorine in a supersonic expansion are produced with an absolute accuracy of 5% in 150-microm pixels by using optical absorption tomography. An incoherent arc-lamp source provides ample ultraviolet radiation for high-resolution optical absorption tomographic measurements. A measurement of the chlorine absorption coefficient is reported.

متن کامل

Weak Force Measurement in Bistable Optomechanical System

One of the main milestones in the study of opto-mechanical system is to increase the sensitivity of weak forces measurement up to the standard quantum limit. We have studied the detection of weak force under a bistable condition in red detuned regime. In this case, dynamics of the system behaves asymptotically similar to stationary state and applying external force affects phase and fluctuation...

متن کامل

طراحی و ساخت نازل جت چند گانه با هدف کاهش صدای ناشی از تفنگ های بادپاش

Background and aims: Discharging compressed air through conventional single jet nozzles or open pipes is a common jet noise in industry. This study is aimed to reduce air blow gun jet noise by designing and fabrication of multiple jet nozzle as a substitute for conventional single jet nozzles.  Methods: One of the most common commercial air blow gun equipped with a conventional single j...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical chemistry chemical physics : PCCP

دوره 15 45  شماره 

صفحات  -

تاریخ انتشار 2013