MRS 2 D quantification vs 1 D quantification
نویسندگان
چکیده
Introduction Many studies related to in vivo proton Magnetic Resonance Spectroscopy (MRS) led to one dimensional (1D) spectroscopic signal quantification methods including LCModel [1] based on frequency domain or QUEST [2] based on time domain. However, standard in vivo MRS acquisitions in 1D spectroscopy present important limitations. 1D MRS spectra usually present rich in vivo metabolic information through complicated, overlapped spectral signatures with large linewidths especially at moderate field. Accurate concentration quantification remains problematic especially for coupled metabolites such as γ-aminobutyric acid (GABA), Glutamine (Gln), Glutamate (Glu), myo-inositol (mI) and Taurine (Tau). To overcome these limitations, the two dimensional (2D) spectroscopy, which is routinely used in organic chemistry, analytical chemistry and structural biology, has great potential to unravel of the spectral information [3] and especially for decorrelation of coupled metabolite concentration. Very few studies (Profit [4]) on 2D spectroscopic signal quantification were performed. This paper introduces a 2D spectroscopic signal quantification based on a global fitting procedure using strong prior-knowledge in the time domain and investigates the correlation between estimate parameters occurring in 1D vs 2D quantification.
منابع مشابه
Quantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...
متن کاملQuantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...
متن کاملERETIC-based glycogen quantification using SNR-enhanced and localized 13C MRS
residual (green): (a), direct acquisition; (b), with NOE and proton decoupling; (c), spectra from (a) enlarged 90-120ppm; (d), spectra from (b) enlarged 90-120ppm. (a) and (b), (c) and (d) are on the same scale, respectively. The ERETIC reference appears at 115ppm, glycogen peaks are centered at 100.5ppm. Figure 1 (top) Voxel of interest in the calf muscle; (bottom) acquisition sequence combini...
متن کاملQuantification of Fetal Brain Lactate with Mr Spectroscopy
Introduction. Magnetic resonance spectroscopy (MRS) has been used to measure cerebral lactate levels in a range of human populations, from elderly stroke patients to pre-term neonates. Although MRS has demonstrated elevated lactate in the sheep fetal brain during hypoxic injury [1] there is little evidence of its application to the measurement of fetal cerebal lactate in humans. The aim of this...
متن کاملEvaluation of Flow Cytometry and Kleihauer Techniques for Quantification of Fetomaternal Hemorrhage: A Prospective Cohort Study in Southwestern Iran
Background: Quantification of fetal red blood cells (RBCs) in maternal blood is of great importance to calculate appropriate dose of post-deliver anti D immunoglobulin in a rhesus D (RhD)-negative woman. Objective: The aim of this study is to evaluate a direct immunofluorescence flow cytometry technique in artificial and clinical samples and compared it t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008