Assessment of reactive hyperaemia using real time zonal echo-planar flow imaging.

نویسندگان

  • Raad H Mohiaddin
  • eter D Gatehouse
  • James C C Moon
  • Mohammed Youssuffidin
  • Guang Z Yang
  • David N Firmin
  • Dudley J Pennell
چکیده

The measurement of limb blood flow at rest and during reactive hyperaemia has potential as a marker of vascular health and endothelial function because it is the stimulus that causes flow-mediated dilatation, commonly measured as brachial arterial reactivity. Because the flow increases are short lived, they represent a significant challenge for measurement by cardiovascular magnetic resonance. In this study we used a real time, single shot zonal echo-planar imaging method (ZEPI) to study reactive hyperaemia in the femoral artery of five healthy volunteers. Flow velocity was measured every 78 msec. Changes in peak forward flow velocity during systole (580 vs. 390 mm/sec, p < 0.01) and minimum flow velocity (160 vs. 100 mm/sec, p < 0.01) were shown. With progressing improvement in spatial resolution, this technique will allow the accurate noninvasive determination of total flow, flow profile, and peak velocities in real time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic flow changes during free breathing exercise, measured with real time MRI

Background Measuring flow with MRI is well established. It is challenging, however, to detect beat-to-beat blood flow response to exercise. We used a new real-time sequence to measure aortic flow during exercise. This phase contrast echo planar imaging (EPI) sequence was previously validated against flow phantoms, and we have recently validated it against the clinical standard sequence in vivo ...

متن کامل

Postocclusive reactive hyperaemia of cutaneous blood flow in premature newborn infants.

Reactive hyperaemia, which occurs after a period of arterial occlusion is the result of an autoregulatory mechanism, involving local factors and autonomic nerve system control. To determine this autoregulatory mechanism in cutaneous blood flow in premature newborns measured the cutaneous reactive hyperaemia response after a 1 min occlusion, using a diode laser Doppler flowmeter applied to the s...

متن کامل

Accelerated 4D flow imaging using randomly undersampled echo planer imaging with compressed-sensing reconstruction

Introduction 2D phase contrast (PC) CMR is currently the standard clinical imaging sequence for evaluation of blood flow [1]. Recently, 3D time-resolved PC CMR (4D-PC) has been used for quantification and visualization of blood flow in all three directions of a volume [2]. However, such acquisitions require long scan times (often 10-20 minutes), which reduces its clinical feasibility and leads ...

متن کامل

Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping: a validation study.

BACKGROUND Flow quantification in real time by phase-contrast MRI (PC-MRI) may provide unique hemodynamic information in congenital heart disease, but available techniques have important limitations. We sought to validate a novel real-time magnetic resonance flow sequence in children. METHODS AND RESULTS In 14 pediatric patients (mean age 5.2+/-2.0 years) with cardiac left-to-right shunt, pul...

متن کامل

Real-time reconstruction and high-speed processing in functional MR imaging.

Access to fully processed activation maps in near real time during a functional MR examination enables run-to-run assessment of results. This is particularly useful in clinical studies, since the results of the functional MR examination can be ascertained before the patient leaves the MR suite, permitting interactive tailoring of the functional MR study. We describe how a real-time MR system ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2002