Personalizing energy expenditure estimation using physiological signals normalization during activities of daily living.
نویسندگان
چکیده
In this paper we propose a generic approach to reduce inter-individual variability of different physiological signals (HR, GSR and respiration) by automatically estimating normalization parameters (e.g. baseline and range). The proposed normalization procedure does not require a dedicated personal calibration during system setup. On the other hand, normalization parameters are estimated at system runtime from sedentary and low intensity activities of daily living (ADLs), such as lying and walking. When combined with activity-specific energy expenditure (EE) models, our normalization procedure improved EE estimation by 15 to 33% in a study group of 18 participants, compared to state of the art activity-specific EE models combining accelerometer and non-normalized physiological signals.
منابع مشابه
Automatic heart rate normalization for accurate energy expenditure estimation. An analysis of activities of daily living and heart rate features.
INTRODUCTION This article is part of the focus theme of Methods of Information in Medicine on "Pervasive Intelligent Technologies for Health". BACKGROUND Energy Expenditure (EE) estimation algorithms using Heart Rate (HR) or a combination of accelerometer and HR data suffer from large error due to inter-person differences in the relation between HR and EE. We recently introduced a methodology...
متن کاملPersonalized cardiorespiratory fitness and energy expenditure estimation using hierarchical Bayesian models
Accurate estimation of energy expenditure (EE) and cardiorespiratory fitness (CRF) is a key element in determining the causal relation between aspects of human behavior related to physical activity and health. In this paper we estimate CRF without requiring laboratory protocols and personalize energy expenditure (EE) estimation models that rely on heart rate data, using CRF. CRF influences the ...
متن کاملEnergy expenditure during daily activities as measured by two motion sensors in patients with COPD.
BACKGROUND In patients with chronic obstructive pulmonary disease (COPD), energy expenditure (EE) assessment during the performance of daily activities is not yet studied in depth. The aim of this study was to determine which daily activities are more demanding to patients with COPD and to compare the accuracy of EE estimation given by the pedometer Digiwalker SW701 (DW) and the multisensor Sen...
متن کاملEstimation of Human Energy Expenditure Using Inertial Sensors and Heart Rate Sensor
This paper presents a method for estimation of human energy expenditure during normal daily activities as well as sports activities using wearable inertial sensor attached to the person’s thigh and chest as well as feasibility analysis of this method to be used as an application on an average smartphone. This is done by using one inertial sensor attached to the person’s thigh (standard smartpho...
متن کاملHow accurate is triaxial RT 3 TM ( RT 3 ) accelerometer for estimating energy expenditure ?
The participants are instructed to remove the RT3 only for sleeping, bathing and swimming activities but some studies have shown the participants remove the accelerometer for longer times. The activities performed while the accelerometer is not being worn and, or energy that was not recorded during this time has never been estimated. This study aimed to assess compliance in using the accelerome...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological measurement
دوره 35 9 شماره
صفحات -
تاریخ انتشار 2014