Process Improvement by Eliminating Mixing of Whole Blood Units after an Overnight Hold Prior to Component Production Using the Buffy Coat Method

نویسندگان

  • Cherie Mastronardi
  • Peter Schubert
  • Elena Levin
  • Varsha Bhakta
  • Qi-Long Yi
  • Adele Hansen
  • Tamiko Stewart
  • Craig Jenkins
  • Wanda Lefresne
  • William Sheffield
  • Jason P. Acker
چکیده

The elimination of a thorough manual mixing of whole blood (WB) which takes place following the overnight hold, but before the first centrifugation step, during buffy coat component production at Canadian Blood Services (CBS) was investigated. WB was pooled after donation and split. Pairs of platelet, red blood cell (RBC), and plasma components were produced, with half using the standard method and half using a method in which the mixing step was eliminated. Quality assessments included yield, pH, CD62P expression and morphology for platelets, hemoglobin, hematocrit, hemolysis, and supernatant K(+) for RBCs, and volume and factor VIII activity levels for plasma. All components, produced using either method, met CBS quality control criteria. There were no significant differences in platelet yield between components produced with and without mixing. A significant difference was seen for RBC hemolysis at expiry (P = 0.03), but for both groups, levels met quality control requirements. Noninferiority of components produced without mixing was confirmed for all parameters. Manual mixing is laborious and has a risk of repetitive strain for production staff and its significance is unclear. Elimination of this step will improve process efficiencies without compromising quality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conversion from Platelet-Rich Plasma Platelet Production to Buffy Coat Platelet Component Production: Benefits and Limitations

Blood transfusion centers are under considerable pressure to produce platelet concentrates with high quality and safety due to the short shelf life of 3-5 days as well as possible bacterial and viral contaminations. For a variety of reasons, many Europeans have changed their methods of component production from whole blood using the North American standard platelet-rich plasma method to the buf...

متن کامل

Quality and standardization in blood component preparation with an automated blood processing technique.

The use of automated blood processors in combination with bottom and top blood containers has been found to improve the standardization and quality of blood components. A study was performed to validate a new type of processor (Optipress II) and compare its performance with a first generation processor (Optipress I). Primary separation on the Optipress II was investigated on 570 mL (+/- 10%) of...

متن کامل

Implementation of buffy coat platelet component production: comparison to platelet-rich plasma platelet production.

BACKGROUND Buffy coat (BC) production of platelets (PLTs) has been successfully used in Europe for more than two decades. Currently, Canadian Blood Services is implementing the BC method. This article summarizes results of the validation testing performed to qualify the process of PLT production from whole blood and compares the quality of PLTs produced in routine production by either the PLT-r...

متن کامل

Conversion from Platelet-Rich Plasma Platelet Production to Buffy Coat Platelet Component Production: Benefits and Limitations

Blood transfusion centers are under considerable pressure to produce platelet concentrates with high quality and safety due to the short shelf life of 3-5 days as well as possible bacterial and viral contaminations. For a variety of reasons, many Europeans have changed their methods of component production from whole blood using the North American standard platelet-rich plasma method to the buf...

متن کامل

Storage of platelet concentrates from pooled buffy coats made of fresh and overnight-stored whole blood processed on the novel Atreus 2C+ system: in vitro study.

BACKGROUND The Atreus 2C+ system (Gambro BCT) automatically separates whole blood (WB) into buffy coat (BC), red blood cells (RBC), and plasma and transfers the components into separate containers. After processing with the Atreus, 4 to 6 BC units can be pooled and processed into leukoreduced platelets (PLTs) by use of the automated OrbiSac BC system (Gambro BCT). The aim of our in vitro study ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013