Novel electromyographic monitoring technique for prevention of right phrenic nerve palsy during cryoballoon ablation.
نویسندگان
چکیده
BACKGROUND Right phrenic nerve palsy (PNP) is the most frequent complication of cryoballoon ablation. Diaphragmatic electromyography can predict PNP with a comfortable safety margin. Our goal was to evaluate the feasibility, efficacy, and safety of electromyography-guided PN monitoring using a novel hepatic vein approach for prevention of PNP. METHODS AND RESULTS This study includes 57 patients (47 males) indicated for cryoballoon ablation for treatment of atrial fibrillation. During right superior pulmonary vein ablation, the PN was paced at 60 beats per minute and diaphragmatic compound motor action potential (CMAP) amplitude was recorded via a quadripolar catheter positioned in a subdiaphragmatic hepatic vein. If a 30% drop in CMAP amplitude was observed, ablation was discontinued with forced deflation. Reliable recording of CMAP before ablation was feasible in 50 of 57 patients (88%). In 7 patients (12%), stable PN pacing could not be achieved. In 44 of 50 patients, CMAP amplitude remained constant during cryoapplication. The mean value of CMAP amplitude was 639.7±240.5 µV; mean variation was 13±4.3%. In 6 of 50 patients (12%) including 5 treated with a 23-mm cryoballoon and 1 with a 28-mm cryoballoon, the 30% reduction cutoff was reached and cryoablation was discontinued. Recovery of CMAP amplitude after discontinuing cryoablation took <60 seconds in all cases. No PNP or complication related to PN monitoring occurred. CONCLUSIONS Recording of diaphragmatic CMAP using a catheter positioned in a subdiaphragmatic hepatic vein seems feasible during cryoballoon ablation. Electromyography-guided PN monitoring seems safe and potentially helpful for prevention of PNP.
منابع مشابه
Clinical experience with a novel electromyographic approach to preventing phrenic nerve injury during cryoballoon ablation in atrial fibrillation.
BACKGROUND Phrenic nerve palsy remains the most frequent complication associated with cryoballoon-based pulmonary vein (PV) isolation. We sought to characterize our experience using a novel monitoring technique for the prevention of phrenic nerve palsy. METHODS AND RESULTS Two hundred consecutive cryoballoon-based PV isolation procedures between October 2010 and October 2013 were studied. In ...
متن کاملElectromyographic monitoring for prevention of phrenic nerve palsy in second-generation cryoballoon procedures.
BACKGROUND Electromyography-guided phrenic nerve (PN) monitoring using a catheter positioned in a hepatic vein can aid in preventing phrenic nerve palsy (PNP) during cryoballoon ablation for atrial fibrillation. We wanted to evaluate the feasibility and efficacy of PN monitoring during procedures using second-generation cryoballoons. METHODS AND RESULTS This study included 140 patients (43 wo...
متن کاملSuccessful transbaffle catheter ablation of pulmonary vein tachycardia.
Mañero M et al. Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: a comparison between the firstand second-generation balloon. Heart Rhythm 2013;10:1318–24. 15. Franceschi F, Dubuc M, Guerra PG, Khairy P. Phrenic nerve monitoring with diaphragmatic electromyography during cryoballoon ablation for atrial fibrillation: the first human application. Heart Rhythm 2011;8:10...
متن کاملCryoballoon ablation of paroxysmal atrial fibrillation: bigger is better and simpler is better.
Pulmonary vein isolation (PVI) is the mainstay of catheter ablation for atrial fibrillation. In an effort to overcome the shortcomings of drawing a continuous line around the pulmonary vein (PV) ostia by point-by-point focal radiofrequency catheter ablation, research in the interventional electrophysiology field currently focuses on developing new energy sources and catheter designs to achieve ...
متن کامل[Phrenic nerve identification with cardiac multidetector computed tomography].
Cryoballoon ablation of the pulmonary veins is a new technique that has proven useful in preventing paroxysmal and persistent atrial fibrillation recurrence. One of the most serious complications of this method is right phrenic nerve palsy. The usefulness of multidetector computed tomography to locate the right phrenic nerve and artery and predict the risk of phrenic nerve palsy during cryoabla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 6 6 شماره
صفحات -
تاریخ انتشار 2013