Hematocrit compensation in electrochemical blood glucose monitoring systems.
نویسندگان
چکیده
BACKGROUND Hematocrit (Hct) is a common interferent in test strips used by diabetes patients to self-monitor blood glucose (BG), resulting in measurement bias. Described is an electrochemical BG monitoring system (OneTouch(®) Verio™) that uses a cofacial sensor design, soluble enzyme chemistry, and multiphasic waveform to effectively correct for patient Hct, delivering an accurate reading for whole BG. METHODS The test strip comprises thin-film gold and palladium electrodes arranged cofacially and spatially separated with a thin spacer. Soluble glucose-sensing reagents are located on the lower palladium electrode and are hydrated on sample application. Blood glucose is oxidized by flavoprotein glucose dehydrogenase, with electron transfer via (reduced) potassium ferrocyanide mediator at the palladium electrode. Hematocrit levels are estimated by measuring oxidation of mediator diffusion to the upper gold electrode during the first portion of the assay. The Hct-corrected glucose levels are determined by an on-meter algorithm. RESULTS In performance testing of blood samples at five glucose levels (30-560 mg/dl) and five Hct levels (19-61%), using 12 test meters and 3 test strip lots, 100% of results (N = 2700) met International Organization for Standardization accuracy criteria (within ± 15 mg/dl and ± 20% of reference results at glucose levels of <75 and ≥75 mg/dl, respectively). Furthermore, 99.9% (2698 of 2700) of results were within ±12 mg/dl and ± 15% of reference values at glucose levels <80 and ≥80 mg/dl, respectively. CONCLUSIONS The technology used in this system provides accurate BG measurements that are insensitive to Hct levels across the range 20-60%.
منابع مشابه
Analysis of an electrochemical blood glucose monitoring system with hematocrit compensation: improved accuracy by design.
The article entitled "Hematocrit Compensation in Electrochemical Blood Glucose Monitoring Systems" by Teodorczyk and colleagues in this issue of Journal of Diabetes Science and Technology demonstrates that the OneTouch(®) Verio™ glucose meter meets current regulatory expectations for glucose meter performance and is relatively free from interference by hematocrit. The lack of influence of hemat...
متن کاملWithin-individual hematocrit variations and self-monitoring of blood glucose.
Many self-monitoring of blood glucose (SMBG) systems have generated artefactually increased glucose results in low-hematocrit patients (e.g., intensive care unit and renal failure patients); conversely, these devices could produce artefactually decreased glucose results in high-hematocrit patients (e.g., neonates). The introduction of hematocrit-independent SMBG systems permits more accurate te...
متن کاملCurrent analytical approaches to measuring blood analytes.
In recent years, laboratory testing in the critical-care setting has increased, a trend due, in part, to the evolution of electrochemical sensors. Various innovations have extended sensor lifetimes, reduced sensor maintenance, and led to the development of single-use and unit-use disposable sensors. These sensor technologies allow the accurate and precise determination, either at or near the be...
متن کاملCystatin C can be measured reliably in capillary blood samples.
1. Sacks DB, Bruns DE, Goldstein DE, Maclaren NK, McDonald JM, Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2002;48:436–72. 2. International Organization of Standardization. In vitro diagnostic test systems—requirements for blood glucose monitoring systems for self-testing in management of diabetes mellitus. IS...
متن کاملReduction of the interferences of biochemicals and hematocrit ratio on the determination of whole blood glucose using multiple screen-printed carbon electrode test strips.
A practical approach to reduce the interferences of biochemicals and hematocrit ratio (Hct%) in the determination of whole blood glucose using multiple screen-printed carbon electrode (SPCE) test strips is described. SPCE test strips with and without glucose oxidase [i.e., GOD(+)-SPCEs and GOD(-)-SPCEs] were used and the chronoamperometric currents of test glucose solutions with various spiked ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of diabetes science and technology
دوره 6 3 شماره
صفحات -
تاریخ انتشار 2012