Dual-Energy Perfusion-CT in Recurrent Pancreatic Cancer - Preliminary Results.

نویسندگان

  • F Fritz
  • S Skornitzke
  • T Hackert
  • H U Kauczor
  • W Stiller
  • L Grenacher
  • M Klauss
چکیده

PURPOSE To evaluate the diagnostic performance of dual energy (DE) perfusion-CT for the differentiation between postoperative soft-tissue formation and tumor recurrence in patients after potentially curative pancreatic cancer resection. MATERIAL AND METHODS 24 patients with postoperative soft-tissue formation in the conventional regular follow-up CT acquisition after pancreatic cancer resection with curative intent were included prospectively. They were examined with a 64-row dual-source CT using a dynamic sequence of 34 DE acquisitions every 1.5 s (80 ml of iodinated contrast material, 370 mg/ml, flow rate 5 ml/s). Weighted average (linearly blended M0.5) 120kVp-equivalent dual-energy perfusion image data sets were evaluated with a body-perfusion CT tool (see above) for estimating blood flow, permeability, and blood volume. Diagnosis was confirmed by histological study (n = 4) and by regular follow-up. RESULTS Final diagnosis was local recurrence of pancreatic cancer in 15 patients and unspecific postoperative tissue formation in 9 patients. The blood-flow values for recurrence tissue trended to be lower compared to postoperative tissue formation with 16.6 ml/100 ml/min and 24.7 ml/100 ml/min, respectively for weighted average 120kVp-equivalent image data, which was not significant (n.s.) (p = 0.06, significance level 0.05). Permeability- and blood-volume values were only slightly lower in recurrence tissue (n.s.). CONCLUSION DE perfusion-CT is feasible in patients after pancreatic cancer resection and a promising functional imaging technique. As only a trend for lower perfusion values in local recurrence compared to unspecific postoperative alterations was found, the perfusion differences are not yet sufficient to differentiate between malignancy and unspecific postoperative alterations for this new technique. Further studies and technical improvements are needed to generate reliable data for this clinically highly relevant differentiation. KEY POINTS • DE Perfusion CT is feasible in patients after pancreatic cancer resection.• While reliable differentiation of unspecific postoperative tissue formation from recurrent malignancy cannot be achieved yet, it is within reach.• DE Perfusion CT has the potential to overcome todays limitations of pure morphological diagnosis of recurrent pancreatic cancer. Citation Format: • Fritz F, Skornitzke S, Hackert T et al. Dual-Energy Perfusion-CT in Recurrent Pancreatic Cancer - Preliminary RESULTS. Fortschr Röntgenstr 2016; 188: 559 - 565.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer

To investigate the potential relationship between perfusion parameters from first-pass dual-input perfusion computed tomography (DI-PCT) and iodine uptake levels estimated from dual-energy CT (DE-CT).The pre-experimental part of this study included a dynamic DE-CT protocol in 15 patients to evaluate peak arterial enhancement of lung cancer based on time-attenuation curves, and the scan time of ...

متن کامل

Perfusion in the Tissue Surrounding Pancreatic Cancer and the Patient's Prognosis

OBJECTIVE The objective was to investigate the relationship between prognosis in case of pancreatic cancer and perfusion in tissue surrounding pancreatic cancer using perfusion CT. METHODS We enrolled 17 patients diagnosed with inoperable pancreatic adenocarcinoma. All patients were examined by perfusion CT and then underwent chemotherapy using gemcitabine. The time density curve (TDC) of eac...

متن کامل

A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study

  In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...

متن کامل

Comparison of brain SPECT with 99mTc-MIBI and CT-scan in discriminating of radiation necrosis and brain tumor recurrence [Persian]

Introduction: 99mTc-MIBI has been proposed for use as an imaging agent for various tumors, including breast cancer, lung cancer, lymphomas, melanomas and brain neoplastic lesions. Brain tumors are very common and radiotherapy being major part of treatment following surgery. After radiotherapy, deteriorating clinical status can be due to either radiation necrosis or recurrent tumor. Comput...

متن کامل

Dual Energy CT Imaging for Suspected Pulmonary Embolism Using a Lower Dose of Contrast Agent

CT is the preferred imaging modality to diagnose pulmonary embolism Evaluation of pulmonary embolism with dual energy CT (DECT) retains diagnostic accuracy using less contrast material than standard CT Virtual monochromatic images, derived from DECT data, show contrast material at greater intensity than standard CT Iodine images show the distribution of contrast material and can be used to asse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

دوره 188 6  شماره 

صفحات  -

تاریخ انتشار 2016