Adaptive interferometry of protein on a BioCD.
نویسندگان
چکیده
Adaptive spinning-disk interferometry is capable of measuring surface profiles of a thin biolayer with subnanometer longitudinal resolution. High-speed phase modulation in the signal beam arises from the moving surface height profile on the spinning disk and is detected as a homodyne signal via dynamic two-wave mixing. A photorefractive quantum-well device performs as an adaptive mixer that compensates disk wobble and vibration while it phase-locks the signal and reference waves in the phase quadrature condition (pi/2 relative phase between the signal and local oscillator). We performed biosensing of immobilized monolayers of antibodies on the disk in both transmission and reflection detection modes. Single- and dual-analyte adaptive spinning-disk immunoassays were demonstrated with good specificity and without observable cross-reactivity. Reflection-mode detection enhances the biosensing sensitivity to one-twentieth of a protein monolayer, creates a topographic map of the protein layer, and can differentiate monolayers of different species by their effective optical thicknesses.
منابع مشابه
Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD
Spinning-disc interferometry (SDI) is a high-speed laser scanning approach to surface metrology that uses common-path interferometry to measure protein spots on a BioCD disk. The measurement sensitivity depends on the scanning pitch and on the time-base. Based on high-resolution laser scanning images of printed antibody spots, we quantify the protein sensitivity as a function of the scan parame...
متن کاملDifferential phase-contrast BioCD biosensor.
Common-path differential phase-contrast interferometry measures the spatial gradient of surface dipole density on a bio-optical compact disk (BioCD) and is sensitive to small changes in dipole density following molecular binding of target molecules out of solution. The recognition molecules are antibody IgG proteins that are deposited in periodic patterns on the BioCD using soft lithography or ...
متن کاملCommon-path interferometric detection of protein monolayer on the BioCD.
The bio-optical compact disk (BioCD) is an optical biosensor that performs common-path molecular interferometry of patterned proteins on a disk spinning at high speed. The common-path configuration makes it ultrastable and allows surface height precision below 10 pm. In this paper we show that two complementary interferometric quadrature conditions exist simultaneously that convert the modulus ...
متن کاملCombined fluorescent and interferometric detection of protein on a BioCD.
We perform simultaneous interferometric and fluorescent detection of molecular protein layers on a BioCD. The 488 nm excitation wavelength of fluorescein also provides the interferometric detection channel that operates in a common-path in-line configuration in the condition of phase quadrature set by a thermal oxide on silicon. The simultaneous acquisition of both channels enables a direct cor...
متن کاملThe BioCD Spinning-Disk Interferometry
High speed interferometry on a spinning disk opens new opportunities for sensitive material metrology. One promising application is fast molecular screening in diagnostic medicine.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 46 22 شماره
صفحات -
تاریخ انتشار 2007