On the optimal acceleration of time-resolved 3D imaging using GRAPPA

نویسندگان

  • B. A. Jung
  • S. Bauer
  • M. Markl
چکیده

Introduction: Time-resolved 3D imaging often suffers from long acquisition times while aiming for high temporal or spatial resolution. To speed up acquisition times parallel imaging techniques for volumetric [1] and time-resolved 2D data acquisition have been introduced [2-4]. However, no systematic investigation of parallel imaging using GRAPPA to reconstruct time-resolved 3D data has been presented to date. Hence, the aim of this work was to explore how to optimally undersample and reconstruct time-resolved 3D data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extending GRAPPA kernels to 4D: application on time-resolved 3D phase contrast imaging

Fig.4: Velocity time courses in a small region-ofinterest in the descending aorta for different reconstruction types. Fig.5: Exemplary plot of pixel-wise velocities of full k-space data vs. PEAKGRAPPA with a 4D-kernel with Rnet=7.2. R Rnet NACS RMSE [%] r2 GRAPPA 4 2.4 24*48 22.6 0.38 PEAK 3D-kernel 8 7.2 12*8 8.7 0.95 PEAK 4D-kernel 8 7.2 12*8 8.1 0.93 PEAK 4D-kernel 12 9.5 12*8 10.4 0.89 Exte...

متن کامل

GRAPPA Reconstruction of Sensitivity Encoded 2D and 3D Proton Echo Planar Spectroscopic Imaging (PEPSI) with SNR Adaptive Recalibrating

M. Rueckert, R. Otazo, S. Posse MIND Institute, Albuquerque, New Mexico, United States, Dept. of Physics and Astronomy, University of New Mexico, Albuquerque, New Mexico, United States, Dept. of Electrical and Computer Engineering, University of New Mexico, Albuquerque, New Mexico, United States, Dept. of Psychiatry, University of New Mexico School of Medicine, Albuquerque, New Mexico, United S...

متن کامل

3D Cartesian and Elliptical GRAPPA Based Spectroscopic Imaging of Gliomas at 3 Tesla

Introduction: 3D MR spectroscopic imaging (3D MRSI) is a powerful tool for diagnosis of brain tumors but long acquisition times in the order of 20-30 minutes causes patient discomfort and motion artifacts. In recent years, several pulse sequence developments proposing different trajectories in k-space such as elliptical sampling (sampling the central elliptical portion of k-space) or echo-plana...

متن کامل

Compressed sensing for rapid late gadolinium enhanced imaging of the left atrium: A preliminary study.

Current late gadolinium enhancement (LGE) imaging of left atrial (LA) scar or fibrosis is relatively slow and requires 5-15min to acquire an undersampled (R=1.7) 3D navigated dataset. The GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) based parallel imaging method is the current clinical standard for accelerating 3D LGE imaging of the LA and permits an acceleration factor ...

متن کامل

Evaluation of 2D multiband EPI imaging for high-resolution, whole-brain, task-based fMRI studies at 3T: Sensitivity and slice leakage artifacts

Functional magnetic resonance imaging (fMRI) studies that require high-resolution whole-brain coverage have long scan times that are primarily driven by the large number of thin slices acquired. Two-dimensional multiband echo-planar imaging (EPI) sequences accelerate the data acquisition along the slice direction and therefore represent an attractive approach to such studies by improving the te...

متن کامل