Oxygen injection site affects FIO2 during noninvasive ventilation.

نویسندگان

  • Bing Dai
  • Jian Kang
  • Na Yu
  • Wei Tan
  • Hong-Wen Zhao
چکیده

BACKGROUND Most portable bi-level positive airway pressure devices are not equipped with air-oxygen blenders for precisely regulating oxygen concentrations, and supplemental oxygen must be added to increase the F(IO2). Very few studies have investigated the factors that affect F(IO2), and their conclusions have been inconsistent. We investigated in vitro noninvasive ventilation (NIV) parameters and their effects on F(IO2), particularly the effect of the oxygen injection site. METHODS NIV was simulated with a test lung and manikin setup. F(IO2) was measured with 4 oxygen injection sites (mask, in front of the exhalation valve, at the humidifier outlet, and proximal to the ventilator), with 3 exhalation valve types, with 2 oxygen flows, and with 4 combinations of inspiratory and expiratory pressure. RESULTS Oxygen flow, inspiratory and expiratory pressure, and exhalation valve type all affected F(IO2). For a given oxygen flow, the oxygen injection site was the most important factor that affected F(IO2). The oxygen injection site that was closest to the patient (on the mask) had the higher F(IO2) (P < .001). CONCLUSIONS The oxygen injection site had the greatest effect on F(IO2) during NIV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of FIO2 on PaCO2 during noninvasive ventilation in patients with COPD.

BACKGROUND The administration of a high FIO2 to COPD patients breathing spontaneously may result in hypercapnia, due to reversal of preexisting regional hypoxic pulmonary vasoconstriction, resulting in a greater dead space. Arterial blood gas trends have not been reported in these patients. In a 31-bed medical ICU in a teaching hospital we prospectively investigated the response of 17 CO2-retai...

متن کامل

Fiber optic bronchoscopy in patients with acute hypoxemic respiratory failure requiring noninvasive ventilation - a feasibility study

INTRODUCTION Noninvasive ventilation (NIV) is a standard procedure in selected patients with acute respiratory failure. Previous studies have used noninvasive ventilation to ensure adequate gas exchange during fiberoptic bronchoscopy in spontaneously breathing hypoxemic patients, thus avoiding endotracheal intubation. However, it is unknown whether bronchoscopy can be performed safely in patien...

متن کامل

For critically ill patients, is high-flow nasal cannula oxygen delivery a suitable alternative to mechanical ventilation?

The purpose of respiratory support is to maintain adequate ventilation and oxygenation. Consequently, ensuring adequate alveolar ventilation is essential for expelling carbon dioxide produced in the human body. Currently, during invasive or noninvasive ventilatory support, minute ventilation is manipulated to ensure adequate alveolar ventilation. For patients with COPD exacerbations, noninvasiv...

متن کامل

Hyperoxia affects the regional pulmonary ventilation/perfusion ratio: an electrical impedance tomography study.

BACKGROUND The way in which hyperoxia affects pulmonary ventilation and perfusion is not fully understood. We investigated how an increase in oxygen partial pressure in healthy young volunteers affects pulmonary ventilation and perfusion measured by thoracic electrical impedance tomography (EIT). METHODS Twelve semi-supine healthy male volunteers aged 21-36 years were studied while breathing ...

متن کامل

Reabsorption atelectasis in a porcine model of ARDS: regional and temporal effects of airway closure, oxygen, and distending pressure.

Little is known about the small airways dysfunction in acute respiratory distress syndrome (ARDS). By computed tomography (CT) imaging in a porcine experimental model of early ARDS, we aimed at studying the location and magnitude of peripheral airway closure and alveolar collapse under high and low distending pressures and high and low inspiratory oxygen fraction (FIO2). Six piglets were mechan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 10  شماره 

صفحات  -

تاریخ انتشار 2013