Heat generated with pegged or keeled glenoid components fixed with defined amounts of cement.

نویسندگان

  • Kelly A Martens
  • Sara L Edwards
  • Imran M Omar
  • Matthew D Saltzman
چکیده

Glenoid component loosening is a common complication of total shoulder arthroplasty and has been associated with the progression of radiolucent lines at the glenoid bone-cement interface. Generation of heat during the exothermic reaction of cement curing may cause osteonecrosis of bone, potentially leading to the development of radiolucent lines. The purpose of this study was to measure the heat generated with various defined amounts of cement used for glenoid component fixation.Ten fresh-frozen cadaver scapulas were randomized to receive a keeled or pegged component with 1, 2, 3, 5, or 7 g of cement for fixation. An infrared camera was used to record the surface temperature generated during the cement curing process to an accuracy of ±2.0°C. Computed tomography was used to evaluate the cement mantle. The maximum temperatures generated did not exceed the critical value for osteonecrosis (56°C) in any of the specimens. The 4 specimens without a complete mantle were those fixed with a smaller quantity of cement (1, 2, or 3 g), and the largest cement mantle thicknesses were observed with the use of 7 g of cement.Up to 7 g of cement can be used without significant concern for thermal necrosis. Incomplete cement mantles were observed when ≤3 g of cement was used for fixation. Our results suggest that surgeons should use >3 g of cement to avoid incomplete cement mantles and that up to 7 g of cement can safely be used for glenoid fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiographic comparison of pegged and keeled glenoid components using modern cementing techniques: a prospective randomized study.

BACKGROUND Modern cementing techniques have improved glenoid fixation, reduced glenoid lucency seen with keeled components, and may eliminate differences attributable to glenoid design. The purpose of this study was to determine the effect of glenoid design on immediate and follow-up radiographic lucency of pegged and keeled glenoid components, using modern cementing techniques. MATERIAL AND ...

متن کامل

In vitro measurement of temperature changes during implantation of cemented glenoid components

BACKGROUND AND PURPOSE It is unclear whether the increase in temperature during cement curing may cause osteonecrosis, leading to loosening of the glenoid component in shoulder arthroplasty. We therefore analyzed the temperature during implantation of cemented glenoid implants. METHODS 8 keeled and 8 pegged glenoids were implanted in standardized fashion in 8 pairs of scapulas. Temperature an...

متن کامل

Incidence of early development of radiolucent lines in keeled polyethylene glenoid components after total shoulder arthroplasty.

Glenoid loosening after total shoulder arthroplasty (TSA) remains a major concern. The purpose of this study was to determine the incidence of radiolucent lines (RLLs) after TSA performed with modern glenoid bone preparation and cement techniques for keeled-back glenoid components. One hundred ten consecutive patients with osteoarthritis were included in this study. Patients had undergone prima...

متن کامل

Radiographic Evaluation of Glenoid Components and its Survivorship

Introduction: This study evaluated the survivorship of pegged versus keeled cemented, all-polyethylene glenoid components using modern cementing and glenoid preparation techniques. Survival of glenoid design was determined according to severity of radiolucencies on follow-up radiographs. Methods: Between April 22, 1999, and February 17, 2009, retrospective chart review was performed on 194 tota...

متن کامل

The radiographic evaluation of keeled and pegged glenoid component insertion.

BACKGROUND Radiolucent lines about the glenoid component of a total shoulder replacement are a common finding, even on initial postoperative radiographs. The achievement of complete osseous support of the component has been shown to decrease micromotion. We evaluated the ability of a group of experienced shoulder surgeons to achieve complete cementing and support in a series of patients managed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2012