Efficient and reproducible high resolution spiral myocardial phase velocity mapping of the entire cardiac cycle

نویسندگان

  • Robin Simpson
  • Jennifer Keegan
  • David Firmin
چکیده

BACKGROUND Three-directional phase velocity mapping (PVM) is capable of measuring longitudinal, radial and circumferential regional myocardial velocities. Current techniques use Cartesian k-space coverage and navigator-gated high spatial and high temporal resolution acquisitions are long. In addition, prospective ECG-gating means that analysis of the full cardiac cycle is not possible. The aim of this study is to develop a high temporal and high spatial resolution PVM technique using efficient spiral k-space coverage and retrospective ECG-gating. Detailed analysis of regional motion over the entire cardiac cycle, including atrial systole for the first time using MR, is presented in 10 healthy volunteers together with a comprehensive assessment of reproducibility. METHODS A navigator-gated high temporal (21 ms) and spatial (1.4 × 1.4 mm) resolution spiral PVM sequence was developed, acquiring three-directional velocities in 53 heartbeats (100% respiratory-gating efficiency). Basal, mid and apical short-axis slices were acquired in 10 healthy volunteers on two occasions. Regional and transmural early systolic, early diastolic and atrial systolic peak longitudinal, radial and circumferential velocities were measured, together with the times to those peaks (TTPs). Reproducibilities were determined as mean ± SD of the signed differences between measurements made from acquisitions performed on the two days. RESULTS All slices were acquired in all volunteers on both occasions with good image quality. The high temporal resolution allowed consistent detection of fine features of motion, while the high spatial resolution allowed the detection of statistically significant regional and transmural differences in motion. Colour plots showing the regional variations in velocity over the entire cardiac cycle enable rapid interpretation of the regional motion within any given slice. The reproducibility of peak velocities was high with the reproducibility of early systolic, early diastolic and atrial systolic peak radial velocities in the mid slice (for example) being -0.01 ± 0.36, 0.20 ± 0.56 and 0.14 ± 0.42 cm/s respectively. Reproducibility of the corresponding TTP values, when normalised to a fixed systolic and diastolic length, was also high (-13.8 ± 27.4, 1.3 ± 21.3 and 3.0 ± 10.9 ms for early systolic, early diastolic and atrial systolic respectively). CONCLUSIONS Retrospectively gated spiral PVM is an efficient and reproducible method of acquiring 3-directional, high resolution velocity data throughout the entire cardiac cycle, including atrial systole.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrogated spiral 3-directional myocardial phase velocity mapping in a single breath-hold

Background Myocardial phase velocity mapping studies have generally been acquired using Cartesian k-space coverage and respiratory gating [1,2]. Acquisition durations for high temporal resolution studies are therefore long and unpredictable and the use of navigators and prospective cardiac gating results in ‘dead-times’ in the cardiac cycle where imaging cannot be performed. We have developed a...

متن کامل

High resolution spiral myocardial phase velocity mapping (PVM) of the entire cardiac cycle

Background Three-directional PVM is capable of measuring regional myocardial velocities. Current techniques use Cartesian k-space coverage, and navigator-gated high spatial and temporal resolution acquisitions are long [1,2]. In addition, they use prospective ECG-gating and analysis of the full cardiac cycle is not possible. The aim of this study is to develop a high temporal and spatial resolu...

متن کامل

Reproducibility of peak and time to peak velocity measurements with a high resolution spiral phase velocity mapping (PVM) sequence

Background Myocardial PVM may be used to assess peak velocities and the times to those peaks (TTP) in order to characterise healthy and pathological regional heart motion [1]. However data on the reproducibility of the technique is limited. A previous breathhold (low resolution) study investigated reproducibility for peak radial and circumferential velocities [2]; however that of TTP measuremen...

متن کامل

Improved method for quantification of regional cardiac function in mice using phase-contrast MRI

Phase-contrast magnetic resonance imaging is a technique that allows for characterization of regional cardiac function and for measuring transmural myocardial velocities in human hearts with high temporal and spatial resolution. The application of this technique (also known as tissue phase mapping) to murine hearts has been very limited so far. The aim of our study was to implement and to optim...

متن کامل

Assessment of myocardial motion in children and young adults using High-temporal resolution MR tissue phase mapping

Background MR Tissue phase mapping (TPM) is a non-invasive tool to detect regional and global myocardial wall motion. Evaluation of myocardial velocity in radial and longitudinal direction throughout the cardiac cycle may help us better understand myocardial mechanics. Our goal is to investigate regional and global left ventricular myocardial motion using respiratory-gated high temporal resolut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013