Exhaled breath condensate in intubated neonates- a window into the lung’s glutathione status

نویسندگان

  • Maria I Rosso
  • Susan Roark
  • Esther Taylor
  • XiaoDu Ping
  • Janine M Ward
  • Katherine Roche
  • Courtney McCracken
  • Lou Ann S Brown
  • Theresa W Gauthier
چکیده

BACKGROUND Analysis of exhaled breath condensates (EBC) is a non-invasive technique to evaluate biomarkers such as antioxidants in the pediatric population, but limited data exists of its use in intubated patients, particularly newborns. Currently, tracheal aspirate (TA) serves as the gold standard collection modality in critically ill newborns, but this method remains invasive. We tested the hypothesis that glutathione status would positively correlate between EBC and TA collections in intubated newborns in the Newborn Intensive Care Unit (NICU). We also hypothesized that these measurements would be associated with alveolar macrophage (AM) glutathione status in the newborn lung. METHODS Reduced glutathione (rGSH), glutathione disulfide (GSSG), and total GSH (rGSH + (2 X GSSG)) were measured in sequential EBC and TA samples from 26 intubated newborns via high performance liquid chromatography (HPLC). Additionally, AM glutathione was evaluated via immunofluorescence. Pearson's correlation coefficient and associated 95% confidence intervals were used to quantify the associations between raw and urea-corrected concentrations in EBC and TA samples and AM staining. Statistical significance was defined as p ≤ 0.05 using two-tailed tests. The sample size was projected to allow for a correlation coefficient of 0.5, with 0.8 power and alpha of 0.05. RESULTS EBC was obtainable from intubated newborns without adverse clinical events. EBC samples demonstrated moderate to strong positive correlations with TA samples in terms of rGSH, GSSG and total GSH. Positive correlations between the two sampling sites were observed in both raw and urea-corrected concentrations of rGSH, GSSG and total GSH. AM glutathione staining moderately correlated with GSSG and total GSH status in both the TA and EBC. CONCLUSIONS GSH status in EBC samples of intubated newborns significantly correlated with the GSH status of the TA sample and was reflective of cellular GSH status in this cohort of neonatal patients. Non-invasive EBC sampling of intubated newborns holds promise for monitoring antioxidant status such as GSH in the premature lung. Further studies are necessary to evaluate the potential relationships between EBC biomarkers in the intubated premature newborn and respiratory morbidities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

سنجش نشانگر زیستی IL-6در هوای بازدمی با استفاده از دستگاه جمع‌آورنده میعانات بازدمی

Background and Objective: The collection of exhaled breath condensate (EBC) is a noninvasive, safe and simple technique to obtain direct samples from lung and use for estimation of the effects of air pollution on human subjects. EBC contains several compounds including simple ions, hydrogen peroxide, proteins, cytokines, deoxyribonucleic acid (DNA), creatine, Electrolytes, trace elements and to...

متن کامل

Methadone concentrations in exhaled breath condensate, serum and urine of patients under maintenance treatment

Drug abuse is a serious problem causing health, economical and psycho-social negative outcomes. Methadone is commonly used drug for management of drug addiction. Exhaled breath condensate (EBC) is a promising non-invasive biological sample which attracted more attention in recent years. This work aimed to extend the applicability of a developed preconcentration – liquid chromatographic method f...

متن کامل

Methadone concentrations in exhaled breath condensate, serum and urine of patients under maintenance treatment

Drug abuse is a serious problem causing health, economical and psycho-social negative outcomes. Methadone is commonly used drug for management of drug addiction. Exhaled breath condensate (EBC) is a promising non-invasive biological sample which attracted more attention in recent years. This work aimed to extend the applicability of a developed preconcentration – liquid chromatographic method f...

متن کامل

Exhaled Breath Condensate

Objective: To examine exhaled breath condensate levels of 8-iso-PGF2ot as a noninvasive quantification of pulmonary oxidant stress in patients with, or at risk for, ARDS/ALI. Methods: Breath condensate was collected from 22 patients with, or at risk for, ARDS/ALI by placing Tygon tubing submerged in an ice bath in line with the expiratory limb of the ventilator circuit. Ten patients without lun...

متن کامل

Collection and analysis of breath and breath condensate exhaled by feral pigeons (Columba livia) and chickens (Gallus domesticus).

Samples of exhaled breath and breath condensate were collected from 20 feral pigeons (Columba livia) while they were anaesthetised and intubated, and when they were kept unanaesthetised in an acrylic box. Samples were also collected from six chickens (Gallus domesticus) while they were kept in an acrylic box. The samples were analysed for pH, nitric oxide (NO), hydrogen peroxide and leukotriene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014