Periprocedural arterial spin labeling and dynamic susceptibility contrast perfusion in detection of cerebral blood flow in patients with acute ischemic syndrome.

نویسندگان

  • Kambiz Nael
  • Arash Meshksar
  • David S Liebeskind
  • Danny J J Wang
  • Benjamin M Ellingson
  • Noriko Salamon
  • Juan Pablo Villablanca
چکیده

BACKGROUND AND PURPOSE To compare the diagnostic performance of arterial spin-labeling (ASL) and dynamic susceptibility contrast (DSC) perfusion in detecting cerebral blood flow (CBF) changes before and after endovascular recanalization in acute ischemic syndrome. METHODS The inclusion criteria for this retrospective study were patients with acute ischemic syndrome who underwent endovascular recanalization and acquisition of both ASL and DSC before and after revascularization. ASL-CBF and multiparametric DSC maps were evaluated for image quality, location, and type of perfusion abnormality. Relative CBF (rCBF) was calculated in the infarction core and hypoperfused areas using coregistered ASL and DSC. Core and hypoperfused rCBF were used for paired pretreatment and posttreatment comparisons. Interobserver and intermodality agreement were evaluated by κ test, and t test was calculated for ASL and DSC rCBF values. RESULTS Twenty-five patients met our inclusion criteria. Five studies were rated nondiagnostic, resulting in 45 pairs of DSC-ASL available for comparison. ASL and DSC agreed on type and location of the perfusion abnormality in 71% and 80% of cases, respectively. The image quality of ASL was lower than DSC, resulting in interobserver variability for the type (κ=0.45) and location (κ=0.56) of perfusion abnormality. ASL was unable to show any type of perfusion abnormality in 11% of patients. In successfully recanalized patients, hyperperfusion (rCBF >1) was detected in 100% on DSC and 47% on ASL. CONCLUSIONS ASL is less sensitive than DSC for detecting rCBF changes in patients with acute ischemic syndrome, particularly with respect to hyperperfusion after successful recanalization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative analysis of hypoperfusion in acute stroke: arterial spin labeling versus dynamic susceptibility contrast.

BACKGROUND AND PURPOSE This study compares the concordance between arterial spin labeling (ASL) and dynamic susceptibility contrast (DSC) for the identification of regional hypoperfusion and diffusion-perfusion mismatch tissue classification using a quantitative method. METHODS The inclusion criteria for this retrospective study were as follows: patients with acute ischemic syndrome with symp...

متن کامل

Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆

The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 ...

متن کامل

The value of arterial spin-labeled perfusion imaging in acute ischemic stroke: comparison with dynamic susceptibility contrast-enhanced MRI.

BACKGROUND AND PURPOSE The purpose of this study was to evaluate the potential clinical value of arterial spin-labeled (ASL) perfusion MRI in acute ischemic stroke (AIS) through comparison with dynamic susceptibility contrast (DSC) enhanced perfusion MRI. METHODS Pseudocontinuous ASL with 3-dimensional background-suppressed gradient and spin echo readout was applied with DSC perfusion MRI on ...

متن کامل

Quantification of blood flow in brain tumors: comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging.

PURPOSE To implement an arterial spin labeling technique that is feasible in routine examinations and to test the method and compare it with dynamic susceptibility-weighted contrast material-enhanced magnetic resonance (MR) imaging for evaluation of tumor blood flow (TBF) in patients with brain tumors. MATERIALS AND METHODS Thirty-six patients with histologically proven brain tumors were exam...

متن کامل

Characterization of gadolinium-based dynamic susceptibility contrast perfusion measurements in permanent and transient MCAO models with volumetric based validation by CASL.

Perfusion imaging is crucial in imaging of ischemic stroke to determine 'tissue at risk' for infarction. In this study we compared the volumetric quantification of the perfusion deficit in two rat middle-cerebral-artery occlusion (MCAO) models using two gadolinium-based contrast agents (P1152 (Guerbet) and Magnevist (Bayer-Schering, Pittsburgh, PA, USA)) as compared with our well established co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 44 3  شماره 

صفحات  -

تاریخ انتشار 2013