Qualitative analysis of polyethylene wear in a bipolar femoral prosthesis: A case report.
نویسندگان
چکیده
We researched the qualitative changes in the polyethylene of a bipolar head retrieved at revision occurring in vivo using optical microscopy and Fourier transform infrared spectroscopy. The bearing surface of the outer head was smooth with no definable scratches delamination. However, the evidence of delamination of the beveled throat region and cracking at the base of the leaf was noticed. The degree of oxidation was different in each area of the polyethylene in the bearing component and that of the rim was shown to be higher than that of the bearing surface. Comparing the rate of ketone and ester, ketone binding was frequently found around the prosthetic rim rather that at the bearing surface. However, the ratio of ester at the surface was higher than that at the deep area of the same rim. We considered these results showed local environmental effects in vivo play a significant role in dictating the response.
منابع مشابه
Investigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation
The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR is Ultra High Molecular Weight Polyethylene (UHMWPE). Pr...
متن کاملFemoral component wear in retrieved hip prostheses.
We retrieved 159 femoral heads at revision surgery to determine changes in surface configuration. Macroscopic wear of the head was observed in three bipolar hip prostheses as a result of three-body wear. There was a considerable change in surface roughness in the internal articulation of bipolar hip prostheses. Roughness in alumina heads was almost the same as that in new cobalt-chromium heads....
متن کاملAcute Disassembly and Dissociation of a Dual-Mobility Next-Generation Prosthesis.
The use of bipolar components in hip surgery was introduced more than 40 years ago with the rationale of a dual-mobility hip implant. This design used a small femoral head that would decrease the rate of wear because of the smaller surface area but would still provide implant stability because of the larger outer shell that articulated with the acetabulum, decreasing dislocation rates. In April...
متن کاملCatastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty
INTRODUCTION Catastrophic polyethylene failure is a rare complication of ceramic-on-polyethylene total hip arthroplasty due to the favorable tribological characteristics of ceramic. Failure of the polyethylene liner can be disastrous, increasing periprosthetic osteolysis, metallosis, and risk of dislocation. Complications associated with ceramic-on-polyethylene articulations have been studied e...
متن کاملA Morlet wavelet signal analysis with a Daubechies filter for the wear assessment of hip prostheses coated with diamond-like carbon by triboadhesion.
In the present work, based on high frequency wavelet analysis of dynamic signals of mechanical systems, a multiple-resolution wavelet analysis is carried out, to the signal obtained from an accelerometer mounted on the structure of a hip prosthesis wearing test device. The prostheses employed had a femoral head made of aluminum oxide and the acetabular cup of ultra-high-molecular-weight polyeth...