Validation of jugular venous flow as an index of total cerebral blood flow.

نویسندگان

  • E M Wilson
  • J H Halsey
  • J J Vitek
چکیده

Validation of Jugular Venous Flow as an Index of Total Cerebral Blood Flow • Values of total cerebral blood flow in man measured by the indicator dilution method are compared with values of total internal jugular venous flow measured by the thermal dilution method. Except in the case of an extremely labile cerebral hemodynamic state, the results agree within the accuracy of the two methods, suggesting that for the supine patient total internal jugular venous flow provides a good index of total cerebral flow. The relatively short measurement time associated with nondiffusible indicators (dye or thermal dilution) facilitates detection of transient changes in total CBF or differential jugular flow that would tend to be averaged out with diffusible indicator methods. A mathematical analysis of the potential errors in the computation of total flow using the average of bilateral jugular venous dilution curves from a unilateral internal carotid injection is presented. This error can be partially corrected if the ratio of flow in one internal jugular to total flow is known. An analysis of potential computational errors under nonsteady state flow conditions (change in flow during the period between alternate carotid injections) is presented. Such flow changes can effect substantial errors in the computation of individual hemispheric or internal jugular flow and smaller errors in the computation of total flow. Additional

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bilateral jugular venous blood flow by thermal dilution.

Bilateral Jugular Venous Blood Flow by Thermal Dilution • Measurements of internal jugular venous flow were made in 12 patients with severe cerebral vascular disease. Flow rates were determined by the thermal dilution method, using room temperature physiological (heparinized) saline as an indicator infused at a constant rate. The major sources of error (indicator mixing) were studied under high...

متن کامل

I-46: Obstetrical Doppler

Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...

متن کامل

Extrajugular pathways of human cerebral venous blood drainage assessed by duplex ultrasound.

Cerebral venous drainage in humans is thought to be ensured mainly via the internal jugular veins (IJVs). However, anatomic, angiographic, and ultrasound studies suggest that the vertebral venous system serves as an important alternative drainage route. We assessed venous blood volume flow in vertebral veins (VVs) and IJVs of 12 healthy volunteers using duplex ultrasound. Measurements were perf...

متن کامل

Effects of short-term exposure to head-down tilt on cerebral hemodynamics: a prospective evaluation of a spaceflight analog using phase-contrast MRI

Alterations in cerebral hemodynamics in microgravity are hypothesized to occur during spaceflight and could be linked to the Visual Impairment and Intracranial Pressure syndrome. Head-down tilt (HDT) is frequently used as a ground-based analog to simulate cephalad fluid shifts in microgravity; however, its effects on cerebral hemodynamics have not been well studied with MRI techniques. Here, we...

متن کامل

Effect of beta-adrenergic blockade with propranolol on cerebral blood flow, autoregulation and CO2 responsiveness.

Cerebral autoregulation and vasomotor responsiveness to carbon dioxide were measured quantitatively in normal baboons and after intravertebral or intravenous of the beta-adrenergic blocking agent, propranolol hydrochloride (Inderal). Continuous measurements were made of cerebral blood flow (CBF: measured as bilateral internal jugular venous outflow using an electromagnetic flowmeter), cerebral ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 1972