Histologic evaluation of bone response to oxidized and turned titanium micro-implants in human jawbone.

نویسندگان

  • Carl-Johan Ivanoff
  • Göran Widmark
  • Carina Johansson
  • Ann Wennerberg
چکیده

PURPOSE To evaluate the human bone tissue response to 2 surfaces (oxidized or turned) on commercially available titanium implants. MATERIALS AND METHODS Screw-type turned (control) and oxidized (test) micro-implants were manufactured in the same manner as commercially available turned and oxidized (TiUnite, Brånemark System) implants. The thickness of the oxide layer of the test implants was on average 10 microm, corresponding to the oxide thickness of the apical part of the TiUnite implant. Twenty patients received 1 test and 1 control micro-implant each during implant surgery. Before placement, the surface topography of the implants was characterized with an optical confocal laser profilometer. After a mean healing period of 6.6 months in the maxilla and 3.5 months in the mandible, the micro-implants and surrounding tissue were removed with a trephine bur. Histologic sections were produced, and the specimens were analyzed histomorphometrically. RESULTS Surface roughness and enlargement were greater for the oxidized implants than for the turned implants. All micro-implants, except for 2 controls, were found to be clinically stable at the time of retrieval. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact for the oxidized implants, whether placed in the maxilla or in the mandible. Significantly more bone was found inside the threaded area for the oxidized implants placed in the mandible and maxilla, but there was no difference between implants with regard to position (maxilla or mandible). DISCUSSION The stronger bone response to the oxidized implants may have contributed to the fact that 2 control implants but no test implants were lost. The reason for these findings may depend on one or multiple differences of the surfaces between test and control implants: (1) the thicker oxide layer itself, (2) increased surface roughness, (3) different surface morphology in terms of porosity, or (4) change in crystal structure. CONCLUSION The present histologic study in human jawbone demonstrated a significantly higher bone response for anodic oxidized titanium implants than for implants with a turned surface.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics of 2 Different Commercially Available Implants with or without Nanotopography

The aim of this study was to assess histologically and histomorphometrically the early bone forming properties after 3 weeks for 2 commercially available implants, one supposedly possessing nanotopography and one without, in a rabbit femur model. Twenty-four implants divided equally into 2 groups were utilized in this study. The first group (P-I MICRO+NANO) was a titanium oxide (TiO2) microblas...

متن کامل

On the Influence of Micro- and Macroscopic Surface Modifications on Bone Integration of Titanium Implants

Background: Osseointegrated titanium implants are routinely used in clinical denstistry as anchorage units for dental prostheses. Although the overall clinical results are good, there are clinical situations when an optimized implant healing is desirable, for instance in order to shorten healing periods and to allow immediate loading. Aims: The present work was undertaken to study the influence...

متن کامل

Fibronectin-Grafted Titanium Dental Implants: An In Vivo Study

Modification of the physiochemical properties of titanium surfaces using glow discharge plasma (GDP) and fibronectin coating has been shown to enhance the surface hydrophilicity, surface roughness, cell adhesion, migration, and proliferation. This in vivo study aimed to evaluate the bone integration efficacy of a biologically modified implant surface. Two different surface-modified implants (Ar...

متن کامل

Implant Surface Micro-Design

The application of implants for dental and orthopedic surgery has increased rapidly within the past few decades. In craniomaxillofacial surgery, different implant systems have been applied, for example, for dental and bone replacement or osteosynthesis plates and screws. These implants may be made of pure titanium or a titanium alloy, usually titanium-aluminumvanadium (Ti-6Al-4V). The surface c...

متن کامل

Ramesh Chowdhary on Efficacy of Implant Thread Design for Bone Stimulation

................................................................. 15 INTRODUCTION ......................................................... 18 Dental Implants ....................................................................18 The bone tissue response to titanium implants ..........................19 Integration of turned titanium implants in bone .........................19 Biomechanics and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2003