Comparison of resistance measured by the interrupter technique and by passive mechanics in sedated infants.

نویسندگان

  • R J Chavasse
  • Y Bastian-Lee
  • P Seddon
چکیده

Airways resistance measured by the interrupter technique (Rint) requires little patient cooperation and has been successfully used in young children, but little studied in infants. The authors aimed to evaluate the measurement of Rint in infants, using a commercially available device (the MicroRint), by comparing it with an established technique to measure respiratory resistance: the single breath occlusion technique (SBT); and a measure of airflow obstruction during forced expiration. Infants <18 months old with a history of wheeze, sedated with triclofos for pulmonary function testing, had measurements taken and compared to Rint (using the MicroRint), respiratory system resistance (Rrs) by SBT, and to maximal flow at functional residual capacity (V'maxFRC). Paired data from 25 of 37 infants studied was obtained. There was a significant difference between Rint (mean 2.94+/-0.68) and Rrs (4.02+/-0.87), but the two measures were strongly correlated (r=0.7). Rint was negatively correlated with V'maxFRC (r=-0.63). Smaller infants failed to trigger the MicroRint. Interrupter resistance values in infants are significantly lower than values of respiratory system resistance obtained by passive mechanics. However, there is a strong correlation between the two measurements, as well as between resistance measured using the interrupter technique and maximal flow at functional residual capacity, which indicates that resistance measured using the interrupter technique may be a useful marker of airway obstruction in infants. There remain a number of theoretical and technical problems which require further exploration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plethysmograph and interrupter resistance measurements in prematurely born young children.

BACKGROUND Airways obstruction in premature infants is often assessed by plethysmography, which requires sedation. The interrupter (Rint) technique does not require sedation, but has rarely been examined in children under 2 years of age. OBJECTIVE To compare Rint results with plethysmographic measurements of airway resistance (Raw) in prematurely born, young children. DESIGN Prospective stu...

متن کامل

Evaluation of the interrupter technique in healthy, unsedated infants.

The interrupter technique may be used to monitor respiratory resistance and does not require active patient cooperation, but has yet to be applied in unsedated, spontaneously breathing infants. The aim of this study was to determine if the interrupter technique is feasible in spontaneously breathing infants and to investigate the influence of facemask types and analysis techniques on the interr...

متن کامل

Respiratory system mechanics in sedated, paralyzed, morbidly obese patients.

The effects of inspiratory flow and inflation volume on the mechanical properties of the respiratory system in eight sedated and paralyzed postoperative morbidly obese patients (aged 37.6 +/- 11.8 yr who had never smoked and had normal preoperative seated spirometry) were investigated by using the technique of rapid airway occlusion during constant-flow inflation. With the patients in the supin...

متن کامل

Differences in airway wall compliance as a possible mechanism for wheezing disorders in infants.

High-frequency input impedance measurements (Z(f)) provide useful noninvasive information on airway geometry and especially airway wall mechanics in the canine and human adult respiratory system. Using the high-speed interrupter technique (HIT), we have shown that it is possible to measure high-frequency Z(f) in infants up to 900 Hz, including antiresonant phenomena which are known to be relate...

متن کامل

What does airway resistance tell us about lung function?

Spirometry is considered the primary method to detect the air flow limitation associated with obstructive lung disease. However, air flow limitation is the end-result of many factors that contribute to obstructive lung disease. One of these factors is increased airway resistance. Airway resistance is traditionally measured by relating air flow and driving pressure using body plethysmography, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2001