Embolus differentiation using multifrequency transcranial Doppler.

نویسنده

  • David H Evans
چکیده

Embolus Differentiation Using Multifrequency Transcranial Doppler To the Editor: Markus and Punter report disappointing results for differentiation between solid and gaseous emboli using both the default settings of the Embo-Dop multifrequency transcranial Doppler system,1 and the modified criteria recommended by Russell and Brucher.2,3 One reason for this poor performance is a fundamental limitation of the multifrequency technique, which cannot be overcome simply by altering the discrimination criteria. The multifrequency technique relies on the ultrasound beam pattern at all measurement frequencies (in the case of the Embo-Dop, 2 MHz and 2.5 MHz) being identical. Any deviation from this will mean that the ratio of the measured values of embolus-to-blood ratio (MEBR) at the 2 frequencies will not only depend on the composition of the embolus, but also on the part of the beam through which the embolus passes. Unfortunately, it is impossible to generate identical ultrasound beams at more than one frequency, because the detailed shape of a beam is determined by interference effects, which are in turn dependent on wavelength, and therefore frequency. In a recent study we compared the beam shapes generated by a multifrequency transducer at 2 MHz and 2.5 MHz, both with and without temporal bone placed in front of the transducer, and found that in either case the effects on the ratio of the MEBRs at the 2 frequencies was to introduce a measurement uncertainty of between 2 dB and 4 dB.4 Correct classification of solid emboli using the Embo-Dop system relies on this ratio lying within a band of values that is only 2.5 to 3 dB wide. This being the case, even if it were possible to make absolutely accurate measurements of MEBR at the 2 frequencies, and assuming the empirical thresholds are absolutely correct, 20% of solid emboli would be misclassified as gaseous.4 In practice, other measurement errors are likely to increase the rate of misclassification, which would fit with the data from Markus and Punter’s study suggesting a misclassification rate of 25.8% for solid emboli.3 The problem of distinguishing between signals from solid and gaseous emboli is clinically important, and the multifrequency technique an interesting approach. Unfortunately, its accuracy is limited by the impossibility of generating identical ultrasound beam shapes at different frequencies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler.

BACKGROUND AND PURPOSE The goal of this study was to assess the first multifrequency transcranial Doppler system specially developed for online automatic detection of cerebral microemboli. METHODS The multifrequency Doppler instrumentation insonates simultaneously with 2.0- and 2.5-MHz frequencies. The detection threshold for embolus detection used in this study was a relative Doppler energy ...

متن کامل

Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.

BACKGROUND AND PURPOSE The aim of this study was to assess the first multifrequency transcranial Doppler system that was specially developed to automatically detect and discriminate between solid and gaseous cerebral microemboli. METHODS The multifrequency transcranial Doppler instrumentation insonates simultaneously with 2.5 and 2.0 MHz. Differentiation between solid and gaseous microemboli ...

متن کامل

Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model.

BACKGROUND AND PURPOSE The detection of circulating particulate cerebral emboli using transcranial Doppler ultrasonography has been recently reported. It has been suggested that this method might allow discrimination between different embolic materials; this would be very useful for selecting specific pharmacological treatment in individual patients. This study was designed to identify those pa...

متن کامل

The effect of velocity on the appearance of embolic signals studied in transcranial Doppler models.

BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can be used to detect circulating cerebral emboli. Recent studies have demonstrated that embolus size is significantly related to both the relative intensity increase and duration of an embolic signal. This may allow information about embolus size to be obtained by analysis of Doppler embolic signals. However, theoretically duration will be...

متن کامل

High-resolution emboli detection and differentiation by characteristic postembolic spectral patterns.

BACKGROUND AND PURPOSE High-intensity transient signals (HITS) detected by transcranial Doppler ultrasonography correspond to microemboli in intracranial arteries. The purpose of this study was to develop new diagnostic criteria for the differentiation of these microembolic signals from artifact, based on a high-resolution analysis of Doppler power spectra in an in vitro model. METHODS Two hu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 2006