Helical CT of the body: are settings adjusted for pediatric patients?

نویسندگان

  • A Paterson
  • D P Frush
  • L F Donnelly
چکیده

OBJECTIVE Our objective was to determine whether adjustments related to patient age are made in the scanning parameters that are determinants of radiation dose for helical CT of pediatric patients. SUBJECTS AND METHODS This prospective investigation included all body (chest and abdomen) helical CT examinations (n = 58) of neonates, infants, and children (n = 32) referred from outside institutions for whom radiologic consultation was requested. Information recorded included tube current, kilovoltage, collimation, and pitch. Examinations were arbitrarily grouped on the basis of the individual's age: group A, 0-4 years; group B, 5-8 years; group C, 9-12 years; and group D, 13-16 years old. RESULTS Thirty-one percent (18/58) of the CT examinations were of the chest and 69% (40/58) were of the abdomen. Sixteen percent (9/58) of the CT examinations were combined chest and abdomen. In 22% (2/9) of these combined examinations, tube current was adjusted between the chest and abdomen CT; in one (11%) of these examinations, the tube current was higher for the chest than for the abdomen portion of the CT examination. The mean tube current setting for chest was 213 mA and was 206 mA for the abdomen, with no evident adjustment in tube current based on the age of the patient. Fifty-six percent of the examinations of neonates, infants, or children 8 years old or younger were performed at a collimation of greater than 5 mm and 53% of these examinations were performed using a pitch of 1.0. CONCLUSION Pediatric helical CT parameters are not adjusted on the basis of the examination type or the age of the child. In particular, these results suggest that pediatric patients may be exposed to an unnecessarily high radiation dose during body CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unnecessary Brain CT scan of Traumatic Pediatric Patients; How to Reduce the Numbers?

There are considerable rates of pediatrics trauma referring emergency department following a traumatic event. The worried parents are requesting for the most sensitive diagnostic test, so emergency physicians ask them to underwent brain computed tomography (CT) scan. Lower threshold of decision making regarding use of brain CT scan results in huge number of normal imaging. On the other hand, ra...

متن کامل

Assessment of compliance levels of effective doses in pediatric CT

Introduction: Computed tomography (CT) is a medical imaging modality that produces 3-D cross-sectional images of tissues using several X-ray projections at different angles. Since its introduction in the 1970s, CT usage has been on the increase for both adults and pediatrics. A major challenge of this modality is the high doses of radiation exposure to patients, especially in p...

متن کامل

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...

متن کامل

Conventional and spiral CT dose indices in Yazd general hospitals, Iran

  ABSTRACT   Background: While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk free. CT is a device with higher patient dose in comparison with other conventional radiological procedures. Is the reduction of exposures by requiring optimization of CT procedures [a principle concern in radiological protection]? In this study, the radiatio...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 176 2  شماره 

صفحات  -

تاریخ انتشار 2001