A Mobile, Multi Camera Setup for 3D Full Body Imaging in Combination with Post-Mortem Computed Tomography Procedures
نویسندگان
چکیده
Three dimensional (3D) models of deceased and injured people in combination with 3D scans of injury causing objects can assist forensic investigations in reconstructing event scenes. Medical imaging techniques, such as post-mortem computed tomography (PMCT) and post-mortem magnetic resonance imaging (PMMR), have been successfully applied to forensic investigations and can add beneficial value to standard autopsy examinations. These imaging modalities can be helpful for 3D reconstructions, especially when internal findings, such as bone fractures, organ damage and internal bleeding, are relevant for the investigation. However, none of these techniques can adequately visualize pattern injuries, such as boot prints and bite marks, or any type of blunt force trauma that forms distinct discolorations on the body’s surface. This is why 3D surface imaging techniques have been introduced to the forensic community. Unfortunately, many commercially available optical scanning systems are cost intensive, time consuming and can only be applied before or after a CT scan has been performed. In this article, we present a mobile, multi-camera rig based on close-range photogrammetry that is inexpensive, fast in acquisition time and can be combined with automated CT scanning protocols. The multi-camera setup comprises seven digital single-lens reflex (DSLR) cameras that are mounted on a mobile frame. Each camera is equipped with a remote control that can trigger the shutter release of all cameras simultaneously. In combination with a medical CT scanner, image acquisition of the multi camera setup can be included into an automated CT scanning procedure. In our preliminary study, textured 3D models of one side of the body were created in less than 15 minutes. The photo acquisition time combined with the modified CT scanning protocols lasted 3:34 minutes whereas the subsequent computation of a textured 3D model based on a low resolution mesh lasted 10:55 minutes. The mobile, multi-camera setup can also be used manually in combination with examination couches, lifting carts and autopsy tables. Finally, the system is not limited to post-mortem investigations but can also be applied to living people and may be used in clinical settings. DOI: 10.15221/16.053 Posted at the Zurich Open Repository and Archive, University of Zurich ZORA URL: https://doi.org/10.5167/uzh-129782 Published Version Originally published at: Kottner, Soren; Ebert, Lars C; Ampanozi, Garyfalia; Braun, Marcel; Thali, Michael J; Gascho, Dominic (2016). A Mobile, Multi Camera Setup for 3D Full Body Imaging in Combination with Post-Mortem Computed Tomography Procedures. In: D’Apuzzo, Nicola. Proceedings of the 7th International Conference on 3D Body Scanning Technologies, Lugano, Switzerland, 30 Nov.-1 Dec. 2016. Lugano: Hometrica Consulting, 53-60. DOI: 10.15221/16.053
منابع مشابه
Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملDosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography
Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes...
متن کاملProtective effects of pomegranate seed oil on ovariectomized rats as a model of postmenopausal osteoporosis: A multi-detector computed tomography evaluation
The pomegranate seed oil (PSO), containing 17-α-estradiol, is one of the newly found phytosterols with synergistic health effects on estrogen related physiological conditions. Herein, PSO was assessed for its potential improving effects on bone characteristics in a rat model of menopausal syndrome. Three month old non-pregnant female Wistar rats (n = 30) were either sham-operated (SHAM) or ovar...
متن کاملAssessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain
Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017