Accuracy of Microwave Cavity Perturbation Measurements

نویسنده

  • R. G. Carter
چکیده

Techniques based on the perturbation of cavity resonators are commonly used to measure the permittivity and permeability of samples of dielectric and ferrite materials at microwave frequencies. They are also used to measure the local electric and magnetic field strengths in microwave structures including the shunt impedances of cavity resonators and the coupling impedances of slow-wave structures. This paper re-examines the assumptions made in the theory of these techniques and provides estimates of the errors of measurement arising from them.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of microwave dielectric properties by an amended cavity perturbation technique

The accuracy of an amendment theory on the cavity perturbation technique for microwave dielectric properties measurements has been studied. The accuracy was confirmed by comparisons of experimental results with those measured by another well known measurement method – post resonance technique. Based on the conventional circular aperture coupling structure, a new equation is proposed to determin...

متن کامل

Electron density and collision frequency of microwave-resonant-cavity-produced discharges

A review of perturbation diagnostics applied to microwave resonant cavity discharges is presented. The classical microwave perturbation technique examines the shift in the resonant frequency and cavity quality factor of the resonant cavity caused by low-electron density discharges. However, the modifications presented allow the analysis to be applied to discharges with electron densities beyond...

متن کامل

Permittivity Measurements with a Resonant Cavity to Develop Human Tissue Phantoms for Microwave Imaging

In order to create human tissue phantoms for a microwave imaging system, a method to determine the complex permittivity is needed. For this reason a cavity perturbation method has been analyzed and used to perform measurements characterizing the complex permittivity of different fluid mixtures. Results show good agreement on single frequency between the measurement with the reentrant cavity and...

متن کامل

Comparative Description of the Microwave Surface Impedance of Nb, BaKBiO, and YBaCuO

Measurements of microwave impedance versus temperature, Zs(Tj, in Nb, Bao 6Ko 4Bi03, and YBa2Cu307-s are given. The measurements were made by the "hot finger" cavity perturbation technique. The electromagnetic properties of Nb are in a good quantitative agreement with the isotropic s-wave BCS theory. This mortel can aise descrihe the experimental

متن کامل

Precision microwave dielectric and magnetic susceptibility measurements of correlated electronic materials using superconducting cavities

We analyze microwave cavity perturbation methods, and show that the technique is an excellent, precision method to study the dynamic magnetic and dielectric response in the GHz frequency range. Using superconducting cavities, we obtain exceptionally high precision and sensitivity for measurements of relative changes. A dynamic electromagnetic susceptibility ζ̃(T ) = ζ′ + iζ′′ is introduced, whic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000