Echocardiographic abnormalities of tricuspid valve motion in pulmonary embolism.
نویسندگان
چکیده
Echocardiographic findings in five patients with pulmonary embolism were studied. Tricuspid echocardiograms showed abnormalities in valve motion, that is a monophasic triangular wave during diastole in all the patients as well as an increased dimension of the right ventricle. An "a' dip of the pulmonary valve echocardiogram was also recognised in all five. Later tricuspid echocardiograms regained the normal M-shaped configuration. The monophasic triangular pattern of the tricuspid valve during diastole may be related to the shorter duration of tricuspid valve opening compared with that of the mitral valve. Tachycardia cannot explain this difference between tricuspid and mitral valve motion, which seems to be caused by a prolonged isovolumic relaxation time of the right ventricle resulting in a delayed opening of the tricuspid valve. These results were obtained by comparing these data with those of control subjects and patients with chronic right ventricular overloading resulting from atrial septal defect.
منابع مشابه
Echocardiographic identification of right-sided cardiac intracavitary thromboembolus in massive pulmonary embolism.
In a patient with clinical features of massive pulmonary embolism, two-dimensional echocardiography demonstrated an echo-dense mass moving freely across the tricuspid valve between the right atrium and right ventricle. This mass was also visualized at angiography, which in addition confirmed extensive pulmonary embolism. At autopsy, the mass was found to be a coiled thrombus, one end of which h...
متن کاملEchocardiography of cardiac valves in pericardial effusion.
Nine adult patients with large pericardial effusions (PE) demonstrated echocardiographic motion abnormalites of cardiac valves in systole. In four cases (Group 1), the abnormal findings consisted of prominent systolic anterior movements of the mitral valve resembling those seen in idiopathic hypertrophic subaortic stenosis. In Group 2(five cases), typical mitral valve prolapse patterns with lar...
متن کاملSpecificity of electrocardiography and echocardiography changes at the patients with the pulmonary embolism.
We evaluated electrocardiographic and echocardiographic changes of 40 patients with pulmonary thrombo-embolism proved by perfusion scintigrams. ECG-changes included sinus tachycardia or absolute tachyarrhythmia de novo, changes type Q1S3T3 and changes in right precordial leads. Analyses of echocardiography included hyperkinesis and then dilatation and apical hypokinesis of right ventricule and ...
متن کاملTricuspid and pulmonic valve echoes in tricuspid and pulmonary atresia.
An echocardiographic pattern of normal tricuspid valve motion in a patient with tricuspid atresia, and pulmonic valve motion in a patient with transposition of the great vessels and pulmonary atresia were documented. The recordings of the valve motion resulted in an initial erroneous diagnosis. Although M-mode echocardiography is very useful for the initial diagnostic evaluation of critically i...
متن کاملDiagnostic Methods Congenital Heart Disease
Two-dimensional echocardiographic features were correlated with surgical findings in 25 patients with Ebstein's anomaly (age 7 days to 71 years). There was excellent agreement between echocardiographic and surgical findings. Echocardiographic observations of anterior leaflet tethering and restriction of motion, as well as small functional right ventricle, were the strongest noninvasively obtain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 47 5 شماره
صفحات -
تاریخ انتشار 1982