Quantitative evaluation of contrast enhanced transcranial Doppler signal using galactose based echo-contrast agent in dogs.

نویسندگان

  • Woojo Chung
  • Hojung Choi
  • Kichang Lee
  • Heechun Lee
  • Mincheol Choi
  • Junghee Yoon
چکیده

Transcranial Doppler ultrasonography (TCD) is hindered by insufficient ultrasound penetration through the temporal bone. The use of echo-contrast agents to enhance the Doppler signal is an important step toward the solution of this problem. The aim of the present study was to investigate the tolerability and diagnostic value of the intravenous echo-contrast agent, Levovist. Levovist was administered intravenously in 8 dogs with two doses (0.2 and 0.3 ml/kg) at different concentrations (300 and 400 mg/ml). In right middle cerebral artery (RMCA), the duration and degree of the signal enhancement were measured by TCD. All 32 administrations of Levovist produced an increase in TCD signal of the RMCA without complications. The first assessable pulse curve could be seen on the screen after 4 to 7 seconds after injection. There was no significant difference of latency period between different concentration and dosage. The signal amplitude was increased homogeneously by more than 30 dB when 0.3 ml/kg with 300 mg/ml concentration of Levovist and 0.2 and 0.3 ml/kg with 400 mg/ml concentration were administered. There was no significant difference in the duration of optimal contrasting between 0.3 ml/kg with 300 mg/ml concentration of Levovist and 0.2 and 0.3 ml/kg with 400 mg/ml concentration. The duration of the signal enhancement was 144 to 422 seconds, depending on the degree of concentration and dose of administration. Optimal TCD signal enhancement of RMCA was obtained using 0.3 ml/kg with 300 mg/ml concentration of Levovist in dogs, which is considered to provide quality visualization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence

Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...

متن کامل

Potential positive MRI contrast agent based on PVP-grafted superparamagnetic iron oxide nanoparticles with various repetition times

Objective(s): The present study aimed to evaluate the capability of synthesized and modified superparamagnetic iron oxide nanoparticles (SPIONs) as the positive contrast agent in magnetic resonance imaging (MRI) by investigating the effect of repetition time (TR) on the MRI signal intensity. Materials and Methods: SPIONs were synthesized using the co-precipitation method, and their surfac...

متن کامل

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

A transpulmonary contrast medium enhances the transcranial Doppler signal in humans.

BACKGROUND AND PURPOSE Transtemporal insonation in transcranial Doppler sonography is often impaired by an insufficient signal-to-noise ratio, especially in elderly patients. A transpulmonary stable air microbubble suspension was injected intravenously in humans as an intracranial ultrasonic contrast agent. METHODS In a clinical phase II study, 20 patients (15 women, 5 men; mean age, 65.5 +/-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of veterinary medical science

دوره 68 6  شماره 

صفحات  -

تاریخ انتشار 2006