Stereoacuity at distance and near.

نویسندگان

  • Bonita P H Wong
  • Russell L Woods
  • Eli Peli
چکیده

PURPOSE Because previous studies have reported conflicting evidence, we examined a possible difference in stereoacuity between distance and near, in particular using a random-dot display. We compared distance and near stereoacuities using identical presentation formats at the two distances. METHODS Twelve young adults with low, stable refractive errors and apparently normal binocular vision participated. Stereoacuity was determined with a Mentor B-VAT II using Random Dot E (BVRDE) and Contour Circles (BVC) stereograms presented on a standard monitor (25 x 19.3 cm) at 518 cm (distance-habitual) and a small monitor (2.0 x 1.4 cm) at 40 cm (near-habitual). To examine whether accommodation-convergence influenced stereoacuity, testing at 40 cm was repeated with the addition of +2.50 DS lenses and base-in prisms (near-compensated) that created the same accommodation and convergence demands as for distance-habitual viewing. RESULTS The two stereotests produced similar findings. Stereoacuity was not significantly different for distance-habitual and near-habitual viewing of the BVRDE (p = 0.43) and BVC (p = 0.79) stereotests. Near-compensated stereoacuity was worse than near-habitual (BVRDE, p = 0.005; BVC, p = 0.004) and distance-habitual (BVRDE, p = 0.05; BVC, p = 0.003) for both stereotests. Because near stereoacuity with yoked prisms (control condition) was the same as without prism (near-habitual), prism-induced optical distortions cannot account for the difference. CONCLUSIONS Stereoacuity was not different at distance and near under normal viewing conditions. The conflict between subject knowledge of target proximity and the optically-induced relaxation of accommodation and convergence, or an inaccurate accommodative-convergence response, might have caused poor near-compensated stereoacuity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability of stereoacuity in intermittent exotropia.

PURPOSE Distance stereoacuity is used to monitor deterioration of intermittent exotropia (IXT), but variability of stereoacuity has not been studied rigorously. The purpose of this study was to assess the variability of stereoacuity over one day in children with IXT. DESIGN Prospective cohort study. METHODS Twelve children with IXT were recruited. Stereoacuity was assessed using the Frisby ...

متن کامل

New Stereoacuity Test Using a 3-Dimensional Display System in Children

The previously developed 3-dimensional (3D) display stereoacuity tests were validated only at distance. We developed a new stereoacuity test using a 3D display that works both at near and distance and evaluated its validity in children with and without strabismus. Sixty children (age range, 6 to 18 years) with variable ranges of stereoacuity were included. Side-by-side randot images of 4 differ...

متن کامل

Improvement in distance stereoacuity following surgery for intermittent exotropia.

PURPOSE To evaluate whether distance stereoacuity improves following surgery for intermittent exotropia using the Frisby Davis Distance (FD2) and Distance Randot stereotests. METHODS Eighteen patients (median age, 24 years; range, 5 to 68 years) with intermittent exotropia were prospectively enrolled. Stereoacuity was measured pre- and 6 weeks postoperatively using the FD2 and Frisby near tes...

متن کامل

Stereoacuity after small aperture corneal inlay implantation

PURPOSE The aim of this study was to compare stereoacuity before and after KAMRA corneal inlay implantation for the correction of presbyopia. PATIENTS AND METHODS This is a prospective study of 60 patients who underwent KAMRA inlay implantation. Patients were examined before and 6 months after surgery for stereoacuity, uncorrected distance visual acuity (UDVA), and uncorrected near visual acu...

متن کامل

Effect of age on adult stereoacuity as measured by different types of stereotest.

AIM To examine how stereoacuity changes with age as measured by a variety of stereotests. METHODS Stereoacuity has been measured in 60 normal subjects aged 17-83 years by a single observer using TNO, Titmus, Frisby near, and Frisby-Davis distance stereotests. Motor fusion was measured at (1/3) metre and 6 metres. RESULTS Overall stereoacuity measured by all tests showed a mild decline with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 79 12  شماره 

صفحات  -

تاریخ انتشار 2002