Quality assurance of concrete foundation elements using an ultrasonic evaluation technique

ثبت نشده
چکیده

In-situ cast concrete deep foundation elements are common in Hong Kong for supporting high-rise buildings. If the quality and structural integrity of these foundation elements are in doubt, the safety of buildings will be jeopardised. Traditionally, a static loading test is the only effective way to verify the loading capacity of a foundation element. In this test, a pile is required to withstand up to two times its designed loading capacity to pass the acceptance criterion. However, the time and expense involved in this procedure can only be justified for a small number of foundation elements and, as such, it is not representative of all foundation elements. Drilling or coring is sometimes applied to evaluate the integrity of concrete foundation elements. Again, there are some restrictions in adopting these methods as these tests are expensive, timeconsuming and cause delays to subsequent works. Furthermore, only limited fractions of the foundation elements are covered in these processes. Recently, technology has advanced so much to allow various low-cost non-destructive testing methods to be carried out on completed foundation elements. Among these methods, Cross-hole Sonic Logging (CSL) is one of the most effective quality assurance methods for testing concrete foundations in terms of assessing the homogeneity and integrity of in-situ concrete foundation elements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nondestructive Evaluation (nde) Methods for Quality Assurance of Epoxy Injection Crack Repairs

A concrete bridge over Interstate 70 east of Denver, Colorado was impacted by a fork lift being transported by a truck moving at a speed of approximately 75 mph. The forklift impacted the east face of the prestressed concrete I-beam bridge girder, resulting in severe cracking and concrete spalling on both sides of the eastmost girder. Polymer-modified repair mortar was used to repair spalled ar...

متن کامل

Are There Any Differences in Seismic Performance Evaluation Criteria for Concrete Arch Dams?

Differences between stress-based and strain-based criteria are investigated in seismic performance evaluation of the arch dams in time domain. A numerical model of the coupled dam-reservoir-foundation system is prepared with the finite element technique. Reservoir is modeled using the Eulerian approach as a compressible domain, and the foundation rock is assumed to be massless. Dynamic equilibr...

متن کامل

Optimal Sensors Location Using Modal Assurance Criterion in Modal Identification of Concrete Gravity Dams

Determination of the optimal sensors location in order to identify of modal parameters, especially in large structures such as dams, is one of the practical issues, which is widely used in damage detection and structural health monitoring. The main objective of this study is to obtain the most information from the dynamic response in a concrete gravity dam by minimizing the non-diagonal element...

متن کامل

Ultrasonic Imaging of Concrete by Synthetic Aperture Focusing Technique Based on Hilbert-Huang Transform of Time Domain Data

For non-destructive evaluation (NDE) of concrete, efficient and accurate imaging techniques are needed for a reliable evaluation of safety and serviceability of structures. Imaging of concrete structures is considered a very challenging task since it is a non-homogeneous material. In this paper, the acoustic (stress wave) technique was applied by using Ultrasonics and Synthetic Aperture Focusin...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006