Recommendation to include methyldibromo glutaronitrile in the European standard patch test series.

نویسندگان

  • Magnus Bruze
  • An Goossens
  • Birgitta Gruvberger
چکیده

The preservative methyldibromo glutaronitrilc (MDBGN) is used non-occupationally and occupationally. High contact allergy rates have been reported when tested in consecutive dermatitis patients as well as clinical cases with allergic contact dermatitis. Up till now there has been no agreement on which patch test preparation to use to trace contact allergy to MDBGN. From the year 2005 on, MDBGN at 0.5% w/w in petrolatum is recommended for the European standard patch test series. The choice of 0.5% is based on consideration of rates of contact allergy, doubtful and irritant reactions, as well as on information on clinical relevance represented by results of a repeated open application test, and patch test concentrations to diagnose allergic contact dermatitis from MDBGN in individual cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeated open application test with methyldibromo glutaronitrile, a multicentre study within the EECDRG.

Contact allergy to and allergic contact dermatitis from methyldibromo glutaronitrile (MDBGN) have frequently been reported. This study was initiated to help determine the optimal patch test preparation for MDBGN. In 51 patients with a doubtful or a positive patch test reaction to at least 1 of 4 test preparations with MDBGN in petrolatum at 1.0% w/w, 0.5%, 0.3% and 0.1%, a repeated open applica...

متن کامل

Allergic contact dermatitis caused by panthenol in a child.

An 11-year-old girl presented with a history of two episodes of facial eczema, which developed 1 day after the application of make-up that was removed with ‘hypoallergenic’ facial wipes. She was patch tested with the British Society for Cutaneous Allergy baseline series, a facial series (Chemotechnique Diagnostics, Vellinge, Sweden), and the facial wipes (the only ‘own’ product made available f...

متن کامل

Quantitative repeated open application testing with a rinse-off product in methyldibromo glutaronitrile-sensitive patients: results of the IVDK.

BACKGROUND While the use of methyldibromo glutaronitrile (MDBGN) in leave-on products is clearly associated with high sensitization or elicitation risk, such a clear-cut relation could be questioned with regard to rinse-off products. OBJECTIVE The objective of this study was to find a maximum non-eliciting concentration for rinse-off products in MDBGN patch test-positive patients. PATIENTS ...

متن کامل

Time trends of contact allergy to the European baseline series in Lithuania.

BACKGROUND Monitoring trends of positive patch test reactions is useful for epidemiological surveillance and contact allergy prevention, and has not previously been reported in Lithuania. OBJECTIVES To examine and compare changes in the prevalence of contact allergy to European baseline series allergens in adults with suspected contact dermatitis during a 9-year period. METHODS In this retr...

متن کامل

Undisclosed methyldibromo glutaronitrile causing allergic contact dermatitis in a NSAID cream.

The allergenicity of methyldibromo glutaronitrile (MD BGN) (1,2-dibromo-2,4-dicyanobutane) is well recognized, both in occupational and in non-occupational settings (1). Used as a preservative, alone or in combination with phenoxyethanol (Euxyl K 400), in metalworking fluids, cosmetics, adhesives, and moist toilet tissues, it was identified as an increasingly important allergen soon after its l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contact dermatitis

دوره 52 1  شماره 

صفحات  -

تاریخ انتشار 2005