A Technique of Direct Tension Measurement of a Strung Fine Wire
نویسندگان
چکیده
We present a new technique of direct measurement of wire tensions in wire chambers. A specially designed circuit plucks the wire using the Lorentz force and measures the frequency of damped transverse oscillations of the wire. The technique avoids the usual time-consuming necessity of tuning circuit parameter to a resonance. It allows a fast and convenient determination of tensions and is straightforward to implement.
منابع مشابه
Experimental Investigation of Surface Roughness and Kerf Width During Machining of Blanking Die Material on Wire Electric Discharge Machine
Wire electric discharge machine (WEDM) is spark erosion in unconventional machining technique to cut hard and the conductive material with a wire as an electrode. The blanking die material SKD 11 is a high carbon and high chromium tool steel with high hardness and high wearing resistance property. This tool steel has broad application in press tools and dies making industries. In this research ...
متن کاملDeveloping Very Fine Nanopearlitic Structure in a High Carbon Steel Wire before Drawing
The effects of steel wire patenting process parameters on very fine interlamellar spacing in the pearlitic steel wire were investigated and the optimized condition of the process was achieved. In this work, the initial nanopearlitic structure was obtained in a 0.72 wt% carbon steel wire before the wire drawing process. The results were the minimum interlamellar spacing of 35 nm and maximum ulti...
متن کاملTemperature measurement of fine wires by photothermal radiometry
This work reports temperature measurement of fine wires using the photothermal radiometry ~PTR! technique. In this method, a laser is employed to create a small periodic temperature perturbation on the wire and thus a small modulation of the thermal emission signal from the wire. The temperature of the wire is derived from the ratio of the photothermal emission signals at two different waveleng...
متن کاملMedial malleolar fractures: a biomechanical study of fixation techniques.
Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO gro...
متن کاملElectrical Resistivity Measurement of the Molten Cordierite Glass Using Two-wire method
Electrical resistivity (ER) is a main parameter in the melting processes of glasses. However, its measurement is difficult at high temperatures. In this study the electrical resistivity of different cordierite glass samples in the molten state was measured in the temperature range of 1100˚C to 1550 ˚C using the two-wire method. It was attempted to decrease the electrical resistivity of the glas...
متن کامل