Measurements with a VSM

نویسنده

  • B. C. Dodrill
چکیده

The last 50 years have seen the development of methods for the digital storage of information. The current method for the storage of digital information is predominantly through the use of magnetic media. Increasing media storage density continues to be a very active area of research. Magnetic media may be divided into particulate and continuous media. Particulate media are comprised of small magnetic particles bonded on a plastic tape or disk, the thickness of the magnetic overcoat is typically on the order of 10,000 Å. Since these are single domain particles, the information is stored by inverting the magnetization of some of the particles. Continuous media are metallic thin films, typically a few hundred angstroms in thickness. Particulate media are advantageous in that they are relatively simple to prepare and are chemically stable, however their recording density is relatively low. Continuous media on the other hand have higher storage densities and the shapes of their hysteresis loops (and hence recording characteristics) may be varied in a controlled way.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Testing and Development of Extended Range Straightness Monitor Systems

This is essentially an archival document that summarizes the results of several tests performed at the Draper Laboratory on extended-range straightness monitor systems during the GEM Muon Alignment R&D activity. Two systems are discussed; standard 3-point LED/Lens/Quad-cell Straight Line Monitors (SLM) with multi-LED blocks, and the Video Straightness Monitor (VSM). Included are measurements of...

متن کامل

A virtual photon source model

A dedicated, efficient Monte Carlo (MC) accelerator head model for intensity modulated stereotactic radiosurgery treatment planning is needed to afford a highly accurate simulation of tiny IMRT fields. A virtual source model (VSM) of a mini multi-leaf collimator (MLC) (the Elekta Beam Modulator (EBM)) is presented, allowing efficient generation of particles even for small fields. The VSM of the...

متن کامل

XRD and VSM Analysis of Nanostructured Cu-Co Alloys

Results of an experimental study of Cu-Co alloys containing 0.3 to 5.0 wt% Co are presented. A series of solution annealed Cu-Co alloys were analyzed by x-ray diffraction (XRD) and vibrating sample magnetometry (VSM). Each Ka doublet was resolved by fitting a Pearson Type VII profile. Precise lattice parameter as a function of cobalt content deviated significantly from Vegard’s law but was in r...

متن کامل

A virtual source model for Monte Carlo simulation of helical tomotherapy

The purpose of this study was to present a Monte Carlo (MC) simulation method based on a virtual source, jaw, and MLC model to calculate dose in patient for helical tomotherapy without the need of calculating phase-space files (PSFs). Current studies on the tomotherapy MC simulation adopt a full MC model, which includes extensive modeling of radiation source, primary and secondary jaws, and mul...

متن کامل

Pattern of substrate utilization in vascular smooth muscle using 13C isotopomer analysis of glutamate.

Although vascular smooth muscle (VSM) derives the majority of its energy from oxidative phosphorylation, controversy exists concerning which substrates are utilized by the tricarboxylic acid (TCA) cycle. We used 13C isotopomer analysis of glutamate to directly measure the entry of exogenous [13C]glucose and acetate and unlabeled endogenous sources into the TCA cycle via acetyl-CoA. Hog carotid ...

متن کامل

Measuring SPIO and Gd contrast agent magnetization using 3T MRI Short title: Measuring SPIO and Gd contrast agent magnetization using 3T MRI

Traditional methods of measuring magnetization in magnetic fluid samples, such as vibrating sample magnetometry (VSM), are typically limited to maximum field strengths of about 1 T. This work demonstrates the ability of MRI to measure the magnetization associated with two commercial MRI contrast agents at 3 T by comparing analytical solutions to experimental imaging results for the field patter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000