Advancements of 2D speckle tracking of arterial wall movements

نویسندگان

  • John Albinsson
  • Hevré Liebgott
چکیده

Cardiovascular diseases are the leading cause of death worldwide. In order to improve the diagnostics and facilitate early interventions of cardiovascular diseases, knowledge about the physiology of the vascular system in both healthy subjects and in subjects with vascular disease is needed. In order to learn more about the physiology of the vascular system and possibly predict cardiovascular diseases, accurate motion estimations of the arterial wall is needed. It has been the aim of this thesis to develop more robust motion estimation methods for use on cine loops to investigate the entire thickness of the arterial wall. In this thesis, the concept of 2D speckle block matching was expanded with the use of an extra kernel for improved robustness and tracking accuracy. It was shown that the use of an extra kernel reduced the motion estimation errors when using a constant kernel size (in silico and on phantoms), or reduced the needed size of the kernel while maintaining the level of motion estimation errors (in vivo). Further, a sub-sample estimation method has been developed which combines two previously presented methods: parabolic and grid slope sub-sample interpolation. It was found that by combining the two methods with a threshold determining which method to use, the proposed method reduced the absolute sub-sample estimation errors in simulated and phantom cine loops. A limited in vivo evaluation of estimations of the longitudinal movement of the common carotid artery using parabolic and grid slope sub-sample interpolation and the proposed method were conducted showing that the method worked well in vivo. The two methods were combined to estimate the longitudinal wall movement of the right common carotid artery on 135 healthy volunteers for improved understanding of the wall movements. The results show that the pronounced variation in patterns of longitudinal movement of the common carotid artery previously shown in young healthy subjects is also present in middle-aged and older healthy subjects. However, the patterns of movement seen in middle-aged and older subjects are different from those commonly seen in young subjects, including the appearance of two additional distinct phases of movement, and thus new complex patterns of movement. The use of ultrasound sampled at a high frame rate has the potential to visualize previously unknown information of the longitudinal movement. An iterative scheme for Lagrangian motion estimations in cine loops collected at high frame rates was developed. A phantom evaluation using ultrasound cine loops showed a reduction by an average 54% in the estimated velocity errors compared to a standard method. It also showed a reduction by an average 73 % in the estimated displacement errors. A feasibility test of tracking in vivo indicated good agreement with motion estimations using a low frame rate cine loop. This thesis thus present and evaluate refined methods to measure vascular function through the estimation of longitudinal movement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

The agreement between 3D, standard 2D and triplane 2D speckle tracking: effects of image quality and 3D volume rate

Comparison of 3D and 2D speckle tracking performed on standard 2D and triplane 2D datasets of normal and pathological left ventricular (LV) wall-motion patterns with a focus on the effect that 3D volume rate (3DVR), image quality and tracking artifacts have on the agreement between 2D and 3D speckle tracking. 37 patients with normal LV function and 18 patients with ischaemic wall-motion abnorma...

متن کامل

Acute myocarditis with normal wall motion detected with 2D speckle tracking echocardiography

UNLABELLED SummaryWe present the case of a 26-year-old male with acute tonsillitis who was referred for coronary angiography because of chest pain, elevated cardiac biomarkers, and biphasic T waves. The patient had no cardiovascular risk factors. Echocardiography showed no wall motion abnormalities and no pericardial effusion. 2D speckle tracking revealed distinct decreased regional peak longit...

متن کامل

Left ventricular strain and strain rate by 2D speckle tracking in chronic thromboembolic pulmonary hypertension before and after pulmonary thromboendarterectomy

BACKGROUND Echocardiographic evaluation of left ventricular (LV) strain and strain rate (SR) by 2D speckle tracking may be useful tools to assess chronic thromboembolic pulmonary hypertension (CTEPH) severity as well as response to successful pulmonary thromboendarterectomy (PTE). METHODS We evaluated 30 patients with CTEPH before and after PTE using 2D speckle tracking measurements of LV rad...

متن کامل

Arterial stiffness in assessment of impaired left atrial function

Arterial stiffness arises as a result of structural and functional changes in the vascular system wall (1). Its measure has gained importance in recent years in the evaluation of vascular risk due to its important correlation with some of the target organ damage that causes hypertension (2, 3) as well as in a non-hypertensive population (4). The ambulatory arterial stiffness index (AASI) is ver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017