Comparison of three cuffed emergency percutaneous cricothyroidotomy devices to conventional surgical cricothyroidotomy in a porcine model.
نویسندگان
چکیده
BACKGROUND Emergency cricothyroidotomy is a potentially life-saving procedure in the 'cannot intubate cannot ventilate (CICV)' scenario. Although surgical cricothyroidotomy remains the technique recommended in many 'CICV' algorithms, the insertion of a tracheostomy as a cannula over a trocar, or using the Seldinger method, may have advantages as they are more familiar to the anaesthetist. We compared the utility of three cuffed cricothyroidotomy devices: cuffed Melker®, Quicktrach 2®, and PCK® devices, with surgical cricothyroidotomy. METHODS After ethical committee approval and written informed consent, 20 anaesthetists performed cricothyroidotomy with all four devices in random order, in a pig larynx and trachea model covered in cured pelt. The primary endpoints were the rate of successful placement of the cricothyroidotomy device into the trachea and the duration of the insertion attempt. RESULTS The Melker® and Quicktrach 2® devices possessed advantages over the surgical approach, in contrast to the PCK® device, which performed less well. All 20 participants inserted the Melker®, with 19 being successful using the surgical approach and the Quicktrach 2®, whereas only 12 successfully inserted the PCK® device (PCK® vs surgical, P=0.02). The Quicktrach 2® had the fastest insertion times and caused least trauma to the posterior tracheal wall. The Melker® was rated highest by the participants and was the only device rated higher than the surgical technique. CONCLUSIONS The Melker® and Quicktrach 2® devices appear to hold particular promise as alternatives to surgical cricothyroidotomy. Further studies, in more clinically relevant models, are required to confirm these initial positive findings.
منابع مشابه
Modified cricothyroidotomy in skill laboratory.
INTRODUCTION Unsuccessful tracheal intubation is considered the most common cause of anesthesia death or brain damage. This study delineates our experience recommending modifications in the cricothyroidotomy technique. METHODS Thirty emergency medicine residents of participated in a study performed on the human simulator moulage in Skill Laboratory of Tabriz University of Medical Science. The...
متن کاملComparison of a percutaneous device and the bougie-assisted surgical technique for emergency cricothyrotomy: an experimental study on a porcine model performed by air ambulance anaesthesiologists
BACKGROUND A large number of techniques and devices for cricothyroidotomy have been developed. In this study, the Portex™ Cricothyroidotomy Kit (PCK, Smiths Medical Ltd, Hythe, UK) was compared with the bougie assisted emergency surgical cricothyrotomy technique (BACT). METHODS Twenty air ambulance anaesthesiologists performed emergency cricothyrotomy on a cadaveric porcine airway model using...
متن کاملBystander cricothyroidotomy with household devices - A fresh cadaveric feasibility study.
INTRODUCTION In various motion pictures, medical TV shows and internet chatrooms, non-medical devices were presented as tools for life-saving cricothyroidotomies. However, there is uncertainty about whether it is possible for a bystander to perform a cricothyroidotomy and maintain gas exchange using improvised household items. This study examines the ability of bystanders to carry out an emerge...
متن کاملA porcine model for teaching surgical cricothyridootomy Modelo porcino no ensino da cricotiroidotomia cirúrgica FERNANDO ANTONIO CAMPELO SPENCER NETTO; PATRICIA ZACHARIAS; RAPHAEL FLAVIO FACHINI CIPRIANI; MICHAEL DE MELLO CONSTANTINO;
Objective: To evaluate the acceptability of an educational project using A porcine model of airway for teaching surgical cricothyroidotomy to medical students and medical residents at a university hospital in southern Brazil. Methods: we developed a teaching project using a porcine model for training in surgical cricothyroidotomy. Medical students and residents received lectures about this surg...
متن کاملWhen Time Counts Rely on Teleflex
Product of the U.S.A. Potential complications may include local or systemic infection, hematoma, extravasations or other complications associated with percutaneous insertion of sterile devices. Teleflex, Arrow, EZ-Connect, EZ-IO, EZ-Stabilier and T.A.L.O.N. are trademarks or registered trademarks of Teleflex Incorporated or its affiliates. © 2015 Teleflex Incorporated. All rights reserved. MC-0...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 106 1 شماره
صفحات -
تاریخ انتشار 2011