We describe a new analytical approach--"capsule chemistry"--for high-speed, selective analysis of a wide variety of analytes. Sequential micro-aliquots of sample and reagents are encapsulated within an inert fluorocarbon liquid. The resulting "test capsule" is introduced into a single analytical flow path, composed of a solid fluorocarbon, Teflon, where the sample is incubated, mixed, reacted, and measured as a moving series of individual tests. These randomly selective assays are processed at a rate of 720 per hour. The unique physical interaction between the liquid and solid fluorocarbon carrier materials effectively prevents detectable "carryover" of aqueous constituents between the successive test capsules. Reactions are monitored through the walls of the Teflon analytical channel at nine in-line detector stations for colorimetric and nephelometric measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Purification of Sesquiterpenes from Saussurea LappaRoots by High Speed Counter Current Chromatography

Sesquiterpenes lactones including costunolide and dehydrocostus lactone, were isolated from Saussurea lappa roots, which had exhibited a wide range of biological activities such as anti-cancer, anti-inflammatory, antiulcer, and immunomodulatory activities. High-speed counter-current chromatography (HSCCC) was applied for the rapid preparative isolation of sesquiterpenes lactones from <...

متن کامل

Purification of Sesquiterpenes from Saussurea LappaRoots by High Speed Counter Current Chromatography

Sesquiterpenes lactones including costunolide and dehydrocostus lactone, were isolated from Saussurea lappa roots, which had exhibited a wide range of biological activities such as anti-cancer, anti-inflammatory, antiulcer, and immunomodulatory activities. High-speed counter-current chromatography (HSCCC) was applied for the rapid preparative isolation of sesquiterpenes lactones from <...

متن کامل

Integrated Genetic Analysis Microsystems

The advent of integrated microsystems for genetic analysis allows the acquisition of information at unprecedented length and time scales. The convergence of molecular biology, chemistry, physics, and materials science is required for their design and construction. The utility of the microsystems originates from increased analysis speed, lower analysis cost, and higher parallelism leading to inc...

متن کامل

Hydrothermal Production of Highly Pure Nano Pyrite in a Stirred Reactor

In this study, pyrite was produced by hydrothermal precipitation from the reaction between FeSO4 and Na2S2O3 at high pressure and high temperature in a stirred reactor. The solid product was purified by means of solvent extraction to remove sulfur. Powder was characterized by X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM) and thermal ...

متن کامل

Design and performance of a miniaturized high-speed continuous-flow analyzer.

Design features and performance of a miniaturized high-speed continuous-flow analyzer are described. Special emphasis is made in the design towards a system that is free from the operational and mechanical complexities found in most of today’s advanced systems. Depending on the particular analyses, sample size varies from 3 to 25 jl and reagent consumption is less than 180 l per sample. Analyse...