Visual intraoperative estimation of cup and stem position is not reliable in minimally invasive hip arthroplasty

نویسندگان

  • Michael Woerner
  • Ernst Sendtner
  • Robert Springorum
  • Benjamin Craiovan
  • Michael Worlicek
  • Tobias Renkawitz
  • Joachim Grifka
  • Markus Weber
چکیده

Background and purpose - In hip arthroplasty, acetabular inclination and anteversion-and also femoral stem torsion-are generally assessed by eye intraoperatively. We assessed whether visual estimation of cup and stem position is reliable. Patients and methods - In the course of a subgroup analysis of a prospective clinical trial, 65 patients underwent cementless hip arthroplasty using a minimally invasive anterolateral approach in lateral decubitus position. Altogether, 4 experienced surgeons assessed cup position intraoperatively according to the operative definition by Murray in the anterior pelvic plane and stem torsion in relation to the femoral condylar plane. Inclination, anteversion, and stem torsion were measured blind postoperatively on 3D-CT and compared to intraoperative results. Results - The mean difference between the 3D-CT results and intraoperative estimations by eye was -4.9° (-18 to 8.7) for inclination, 9.7° (-16 to 41) for anteversion, and -7.3° (-34 to 15) for stem torsion. We found an overestimation of > 5° for cup inclination in 32 hips, an overestimation of > 5° for stem torsion in 40 hips, and an underestimation < 5° for cup anteversion in 42 hips. The level of professional experience and patient characteristics had no clinically relevant effect on the accuracy of estimation by eye. Altogether, 46 stems were located outside the native norm of 10-20° as defined by Tönnis, measured on 3D-CT. Interpretation - Even an experienced surgeon's intraoperative estimation of cup and stem position by eye is not reliable compared to 3D-CT in minimally invasive THA. The use of mechanical insertion jigs, intraoperative fluoroscopy, or imageless navigation is recommended for correct implant insertion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of a Digital Protractor and a Spirit Level to Determine the Intraoperative Anteversion of Femoral Component during Cemented Hip Hemiarthroplasty: a Prospective Clinical Trial

Background: Femoral stem anteversion during hip arthroplasty is generally estimated by eye intraoperatively and hasproven to be different from targeted values. This study aims to determine the accuracy of a novel technique using adigital protractor and a spirit level to improve surgeons’ estimation of stem anteversion.Methods: A prospective non-randomized study was conducted a...

متن کامل

Native femoral anteversion should not be used as reference in cementless total hip arthroplasty with a straight, tapered stem: a retrospective clinical study

BACKROUND Improper femoral and acetabular component positioning can be associated with instability, impingement, component wear and finally patient dissatisfaction in total hip arthroplasty (THA). The concept of "femur first"/"combined anteversion", incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position of the stem relative to the cup intrao...

متن کامل

Stem torsion in total hip replacement

BACKGROUND AND PURPOSE The clinical results of THR may be improved by correct femoral torsion. We evaluated the stem position by postoperative CT examination in 60 patients. METHODS 60 patients requiring total hip arthroplasty were prospectively enrolled in this study. Minimally invasive THR was performed (anterior approach) in a lateral decubitus position and each patient underwent a postope...

متن کامل

Total Hip Arthroplasty Using Two-Incision Technique

BACKGROUND To evaluate the effectiveness of minimally invasive surgery total hip arthroplasty (THA) using the two-incision technique as described by Mears. METHODS From January 2003 to December 2006, sixty-four patients underwent total hip arthroplasty using the one-incision (group I) and two-incision (group II) technique by one surgeon. There were 34 hips in group I and 30 hips in group II. ...

متن کامل

Accuracy of Image-based Computer Assisted Surgery in Acetabular Cup Placement for Supine Two-incision Total Hip Arthroplasty

Introduction: Supine patient positioning in conjunction with twoincision minimally invasive surgery (MIS-2 incision) total hip arthroplasty (THA) increases difficulty of accurate and repeatable cup orientation in accordance with pre-operative planning. Investigators have suggested advantages of utilizing computer assisted orthopaedic surgery (CAOS) to successfully eliminate extreme outlying ace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2016