Flow-dependent changes in Doppler-derived aortic valve effective orifice area are real and not due to artifact.

نویسندگان

  • Lyes Kadem
  • Régis Rieu
  • Jean G Dumesnil
  • Louis-Gilles Durand
  • Philippe Pibarot
چکیده

OBJECTIVES We sought to determine whether the flow-dependent changes in Doppler-derived valve effective orifice area (EOA) are real or due to artifact. BACKGROUND It has frequently been reported that the EOA may vary with transvalvular flow in patients with aortic stenosis. However, the explanation of the flow dependence of EOA remains controversial and some studies have suggested that the EOA estimated by Doppler-echocardiography (EOA(Dop)) may underestimate the actual EOA at low flow rates. METHODS One bioprosthetic valve and three rigid orifices were tested in a mock flow circulation model over a wide range of flow rates. The EOA(Dop) was compared with reference values obtained using particle image velocimetry (EOA(PIV)). RESULTS There was excellent agreement between EOA(Dop) and EOA(PIV) (r2 = 0.94). For rigid orifices of 0.5 and 1.0 cm2, no significant change in the EOA was observed with increasing flow rate. However, substantial increases of both EOA(Dop) and EOA(PIV) were observed when stroke volume increased from 20 to 70 ml both in the 1.5 cm2 rigid orifice (+52% for EOA(Dop) and +54% for EOA(PIV)) and the bioprosthetic valve (+62% for EOA(Dop) and +63% for EOA(PIV)); such changes are explained either by the presence of unsteady effects at low flow rates and/or by an increase in valve leaflet opening. CONCLUSIONS The flow-dependent changes in EOA(Dop) are not artifacts but represent real changes in EOA attributable either to unsteady effects at low flow rates and/or to changes in valve leaflet opening. Such changes in EOA(Dop) can be relied on for clinical judgment making.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler assessment of prosthetic valve orifice area. An in vitro study.

BACKGROUND Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. METHODS AND RESULTS Doppler-estimated valve areas were studied for their agreement with catheter-derived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-...

متن کامل

Doppler Assessment of Prosthetic Valve Orifice Area

Background. Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. Methods and Results. Doppler-estimated valve areas were studied for their agreement with catheterderived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-2...

متن کامل

Estimation of aortic valve effective orifice area by Doppler echocardiography: effects of valve inflow shape and flow rate.

BACKGROUND The effective orifice area (EOA) is the standard parameter for the clinical assessment of aortic stenosis severity. It has been reported that EOA measured by Doppler echocardiography does not necessarily provide an accurate estimate of the cross-sectional area of the flow jet at the vena contracta, especially at low flow rates. The objective of this study was to test the validity of ...

متن کامل

A new approach for the evaluation of the severity of coarctation of the aorta using Doppler velocity index and effective orifice area: in vitro validation and clinical implications.

Early detection and accurate estimation of COA severity are the most important predictors of successful long-term outcome. However, current clinical parameters used for the evaluation of the severity of COA have several limitations and are flow dependent. The objectives of this study are to evaluate the limitations of current existing parameters for the evaluation of the severity of coarctation...

متن کامل

Comparison of valve resistance with effective orifice area regarding flow dependence.

Aortic valve resistance has been proposed to represent the severity of aortic stenosis because some studies observed that it was less affected by change in flow than the valve-effective orifice area, but this issue remains controversial. The objective of this study was to systematically analyze the theoretical and practical determinants of these parameters in relation to changes in flow. Valve ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2006