Flow Injection Analysis with Tensammetric Detection for the Determination of Detergents
نویسندگان
چکیده
A straightforward flow injection method for the tensammetric determination of surfactants is described. The flow-through cell is equipped with a mercury-coated gold electrode as the working electrode. Ionic as well as nonionic surfactants can be determined in the concentration range 10~5-104 M. The calibration graph is not linear but with an approximation by a polynomial or a cubic spline function, correct results can be obtained with an accuracy of *4%. The sample rate is about 60 h-l.
منابع مشابه
Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine
A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...
متن کاملUltra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis
Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...
متن کاملFLOW INJECTIOW DETERMINATION OF FLUORIDE BY MURTN-ALUMINUM REAGEM WITH SPECTROEUORIMIETRIC DETECTION
A flow injection system is reported for the determination of fluoride based on its effects on the fluorescence intensity of Al-morin complex at pH 3.0 in ethanol-warn mixture. The effect of important parameters such as excitation and emission wavelengths, pH, reagents concenkations, flow rate of the carrier stream, sample injection volume, time of measurepent and interferences are reported. ...
متن کاملFlow Injection Spectrophotometric Determination of Sulphide by Catalytic Reduction of Toluidine Blue
Sulphide was determined spectrophotometrically at 628 nm and pH 6.7 based on its catalytic reduction of toluidine blue in the presence of Se(IV) using a flow injection system. After optimization of the measuring conditions the calibration curve was found linear up to 25 mg/mL and the detection limit was 0.3 mg/mL (30 mL injections). The ...
متن کاملSurfactants Analysis from Natural Waters Using Nonfaradaic Processes
Voltammetric measurements of dissolved surface-active substances in aqueous solutions, as specific commercial detergents, are described in the present paper. Two voltammetric methods based on the adsorption phenomena at mercury electrode/aqueous solution interface were performed in order to obtain the analytical signal for the detergent analysis. The first method was direct current polarography...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -