Reference values from M-mode and Doppler echocardiography for normal Syrian hamsters.
نویسندگان
چکیده
AIMS Echocardiography has recently been introduced to small animal research, allowing serial measurements of cardiac diseases. In addition, the hamster model has been increasingly used, as it mimics many human heart conditions. However, no reference range of echocardiographic values reflecting normal left ventricular (LV) function exists for hamsters. The purpose of this study was to provide one. METHODS AND RESULTS The study group consisted of 118 10-week-old, female, Syrian golden hamsters, which underwent high-resolution echocardiography. LV mass was calculated using the corrected cube formula, and LV systolic and diastolic function were assessed by fractional shortening and mitral inflow pulsed-wave Doppler, respectively. The myocardial performance index (MPI) measured the time spent in isovolumic activity and reflected both systolic and diastolic function. The mean+/-SD LV mass, fractional shortening, and MPI were 0.19+/-0.04 g, 44.7+/-6.6%, and 0.39+/-0.1, respectively. E and A waves were differentiated in 52% of all animals. Logistic regression adjusted with a cutoff of 378 bpm revealed that the risk of E/A wave fusion was 35 times greater (95% CI: 12.6; 98.4) in animals with a heart rate >378 bpm. CONCLUSION This study documents echocardiographic characteristics in normal Syrian hamsters, which can be used as control values for future studies.
منابع مشابه
Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat
Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...
متن کاملEchocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs
Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...
متن کاملComparison between M-Mode and Doppler echocardiography in diagnosis
Introduction: Patent ductus arteriosus (PDA) is the persistence of a normal fetal structure between left pulmonary artery and descending aorta. Persistence of this fetal structure beyond 10 days of life is considered abnormal. In this study we compared M-Mode and Doppler echocardiography in diagnosis of PDA in children at Aliasghar Hospital in Zahedan and Children hospital in Bandar Abbas for...
متن کاملNormal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran
The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...
متن کاملReference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology
دوره 6 1 شماره
صفحات -
تاریخ انتشار 2005