Contact Geometry Affects Lesion Formation in Radio-Frequency Cardiac Catheter Ablation
نویسندگان
چکیده
One factor which may be important for determining proper lesion creation during atrial ablation is catheter-endocardial contact. Little information is available that relates geometric contact, depth and angle, to ablation lesion formation. We present an electrothermal computer model of ablation that calculated lesion volume and temperature development over time. The Pennes bioheat equation was coupled to a quasistatic electrical problem to investigate the effect of catheter penetration depth, as well as incident catheter angle as may occur in practice. Biological experiments were performed to verify the modelling of electrical phenomena. Results show that for deeply penetrating tips, acute catheter angles reduced the rate of temperature buildup, allowing larger lesions to form before temperatures elevated excessively. It was also found that greater penetration did not lead to greater transmurality of lesions. We conclude that catheter contact angle plays a significant role in lesion formation, and the time course must be considered. This is clinically relevant because proper identification and prediction of geometric contact variables could improve ablation efficacy.
منابع مشابه
Respiratory motion influence on catheter contact force during radio frequency ablation procedures
Minimally invasive catheter ablation is a common treatment option for atrial fibrillation. A common treatment strategy is pulmonary vein isolation. In this case, individual ablation points need to be placed around the ostia of the pulmonary veins attached to the left atrium to generate transmural lesions and thereby block electric signals. To achieve a durable transmural lesion, the tip of the ...
متن کاملMRI-conditional catheter sensor for contact force and temperature monitoring during cardiac electrophysiological procedures
Background MR-guided cardiac electrophysiological (EP) ablations has drawn increasing attention from both the MRI and EP communities, as high-contrast MR images provide images that couple anatomical information with lesion efficacy [1]. Catheter manipulation can be challenging for cardiac electrophysiologists as conventional electroanatomical maps, frequently include false space. Perforation of...
متن کاملPossibility of contact force monitoring during catheter ablation of ventricular tachycardia
Nowadays, electroanatomical mapping system are widely used to clarify arrhythmic substrates and identify the target of ablation not only in patients with supraventricular tachycardia or atrial fibrillation but also ventricular tachycardia. To achieve good results in the procedure, it is important to obtain precise mapping information and to deliver adequate radiofrequency energy. Although it is...
متن کاملGiant J-wave (Osborn wave) unrelated to hypothermia.
contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol 2008;1:354–62. 3. Shah DC, Leo G, Aeby N, Le Royer E, Sunthorn H, Burri H et al. Evaluation of a new catheter sensor for real-time measurement of tissue contact. Heart Rhythm 2006;3:S75–6. Abstract. 4. Ikeda A, Nakagawa H, Sha...
متن کاملFactors Influencing Lesion Formation During Radiofrequency Catheter Ablation
In radiofrequency (RF) ablation, the heating of cardiac tissue is mainly resistive. RF current heats cardiac tissue and in turn the catheter electrode is being heated. Consequently, the catheter tip temperature is always lower--or ideally equal--than the superficial tissue temperature. The lesion size is influenced by many parameters such as delivered RF power, electrode length, electrode orien...