Contrast-enhanced PET/MR imaging versus contrast-enhanced PET/CT in head and neck cancer: how much MR information is needed?

نویسندگان

  • Felix P Kuhn
  • Martin Hüllner
  • Caecilia E Mader
  • Nikos Kastrinidis
  • Gerhard F Huber
  • Gustav K von Schulthess
  • Spyros Kollias
  • Patrick Veit-Haibach
چکیده

UNLABELLED Considering PET/MR imaging as a whole-body staging tool, scan time restrictions in a single body area are mandatory for the cost-effective clinical operation of an integrated multimodality scanner setting. It has to be considered that (18)F-FDG already acts as a contrast agent and that under certain circumstances MR contrast may not yield additional clinically relevant information. The concept of the present study was to understand which portions of the imaging information enhance the sensitivity and specificity of the hybrid examination and which portions are redundant. METHODS One hundred fifty consecutive patients referred for primary staging or restaging of head and neck cancer underwent sequential whole-body (18)F-FDG PET with CT-based attenuation correction, contrast-enhanced (ce) CT, and conventional diagnostic MR imaging of the head and neck in a trimodality PET/CT-MR system. Assessed were image quality, lesion conspicuity, diagnostic confidence, and the benefit of additional coronal and sagittal imaging planes in cePET/CT, PET/MR imaging with only T2-weighted fat-suppressed images (T2w PET/MR imaging), and cePET/MR imaging. RESULTS In 85 patients with at least 1 PET-positive lesion, 162 lesions were evaluated. Similar robustness was found for CT and MR image quality. T2w PET/MR imaging performed similarly to (metastatic lymph nodes) or better than (primary tumors) cePET/CT in the morphologic characterization of PET-positive lesions and permitted the diagnosis of necrotic or cystic lymph node metastasis without application of intravenous contrast medium. CePET/MR imaging yielded a higher diagnostic confidence for accurate lesion conspicuity (especially in the nasopharynx and in the larynx), infiltration of adjacent structures, and perineural spread. CONCLUSION The results of the present study provide evidence that PET/MR imaging can serve as a legitimate alternative to PET/CT in the clinical workup of patients with head and neck cancers. Intravenous MR contrast medium may be applied only if the exact tumor extent or infiltration of crucial structures is of concern (i.e., preoperatively) or if perineural spread is anticipated. In early assessment of the response to therapy, in follow-up examinations, or in a whole-body protocol for non-head and neck tumors, T2w PET/MR imaging may be sufficient for coverage of the head and neck. The additional MR scanning time may instead be used for advanced MR techniques to increase the specificity of the hybrid imaging examination.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

Objective(s): In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT), complicating hepatocellular carcinoma (HCC) in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), which is a comb...

متن کامل

A Prospective Study Comparing Functional Imaging (18F-FDG PET) Versus Anatomical Imaging (Contrast Enhanced CT) in Dosimetric Planning for Non-small Cell Lung Cancer.

 Objective(s): 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) is a well-used and established technique for lung cancer staging. Radiation therapy requires accurate target volume delineation, which is difficult in most cases due to coexisting atelectasis. The present study was performed to compare the 18F-FDG PET-CT with contrast enhanced computed tomogr...

متن کامل

New directions in head and neck imaging.

Computerized tomography (CT) and magnetic resonance imaging (MRI), positron emission tomography (PET) and the hybrid modality of PET/CT are sensitive and reliable tools for detection and staging of head and neck cancers. This article describes the role of PET/CT in initial staging of head and neck squamous cell carcinoma, the utility of CT/MR perfusion imaging in qualitative analysis of tumor t...

متن کامل

Contrast-enhanced FDG-PET/CT vs. SPIO-enhanced MRI vs. FDG-PET vs. CT in patients with liver metastases from colorectal cancer: a prospective study with intraoperative confirmation.

BACKGROUND The choice of imaging before liver surgery is debated regarding the use of magnetic resonance (MR) imaging, computed tomography (CT), and positron emission tomography (PET). No studies have compared contrast-enhanced PET/CT with superparamagnetic iron oxide (SPIO)-enhanced MR imaging. PURPOSE To compare PET/CT with superparamagnetic iron oxide (SPIO)-enhanced MR imaging, PET, and C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 55 4  شماره 

صفحات  -