Stability Indicating High-Performance Liquid Chromatography Method for the Estimation of Artemether in Capsule Dosage Forms

نویسندگان

  • A Shrivastava
  • R Issarani
  • BP Nagori
چکیده

A new simple, sensitive, precise, and accurate high-performance liquid chromatography (HPLC) method of analysis for artemether both as a bulk drug and in capsule formulations was developed and validated. The method employed mobile phase acetonitrile (ACN) and buffer in the ratio 65:35 of pH 6.5 adjusted with tryethylamine. The linear regression analysis data for the calibration plots showed good linear relationship with r(2) = 0.9996 in the concentration range 250-750 μg/ml. The mean value slope and intercept were 9355.5 and -93.5, respectively. The method was validated for precision, accuracy, and recovery studies. Limit of detection (LOD) and Limit of quantitation (LOQ) for artemether were found to be 21.83-750 μg/ml, respectively. The method has been successfully applied in the analysis of marketed capsule formulations. The presented method was found to be reliable to separate all the degradents from all the stress conditions with resolution of more than 1.5 showing that it is a stability indicating method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability-indicating HPLC method for quantification of celecoxib and diacerein along with its impurities in capsule dosage form.

A novel stability-indicating reverse phase high performance liquid chromatography method was developed and validated for the simultaneous determination of Celecoxib (CEL) and Diacerein (DIN) and its impurities in capsule dosage form. The method was developed using L1 column with gradient using the mobile phase consist of Solution A (pH = 2.3 buffer) and Solution B (methanol and acetonitrile; 50...

متن کامل

A Validated Reverse Phase Hplc Method for the Simultaneous Estimation of Artemether and Lumefantrine in Pharmaceutical Dosage Forms

A simple, sensitive and precise reverse phase high performance liquid chromatographic method has been developed for the simultaneous estimation of Artemether and Lumefantrine in pharmaceutical dosage forms. The mobile phase consisted of Acetonitrile: buffer (0.1% v/v ortho phosphoric acid, PH – 3) in the ratio of 60:40 v/v delivered at a flow rate of 1.5 ml / min and wavelength of detection at ...

متن کامل

Simulataneous Analysis of Trimethoprim and Sulphamethoxazole Drug Combinations in Dosage Forms by High Performance Liquid Chromatography

A sensitive high performance liquid chromathography (HPLC) analytical procedure was developed for the quantitive determination of trimethoprim (TM* and sulphamethoxazole (SM) in commercial dosage forms. C18 analytical column (stainless steel, 25 cm * 4.6 mm i.d.) was packed with 5-*m particles of the reversed phase material and used for assays. Mobile phase containing 0.025 M sodium phosphate...

متن کامل

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

Stability-indicating UFLC method for uncoupling and estimation of impurities in clopidogrel, aspirin and omeprazole in their tablet dosage form using PDA detection

In this paper a fast and novel stability-indicating ultra fast LC method for separation and estimation of impurities in clopidogrel and aspirin in their combined tablet dosage form and omeprazole was developed. The separation of USP related substances of clopidogrel (A, B and C), aspirin (D), omeprazole (A, B and C) and few other unknown impurities was detected by using ultra fast liquid chroma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2010