SIMULATION and ANALYSIS of PARALLEL MANIPULATOR for MANOEUVRING LAPAROSCOPIC CAMERA - CAD BASED APPROACH
نویسنده
چکیده
The inconvenience of laparoscopic operations lies mainly in the difficulties in mutual understanding between the surgeon and the camera assistant that manoeuvres the laparoscope camera according to the surgeon’s instructions .Another problem arises when the operation had to be performed for many hours.[1] In these cases the camera image tends to become unsteady due to fatigue of the camera assistant. The self-camera control, give more stability of the laparoscopic image, A robotic camera Assistant(parallel manipulator) directly under surgeon’s control can help the surgeon control the view better.In this paper a parallel robot is simulated for the manipulation of laparoscopic camera and Two dimentional workspace generated is indicated and velocity ,acceleration ,displacement graphs are shown and analysis is done using ANSYS. keywords: laproscopic camera,parallel manipulator,solid works,simulation,ANSYS I.INTRODUCTION TO ROBOTS FOR MEDICAL APPLICATIONS In the current era of evidence based medicine enthusiasm for laparoscopic surgery is rapidly gaining momentum. There is an immense amount of literature showing advantages of minimal access surgery and acceptance by almost all the surgical speciality[1]. The advantages of laparoscopic surgery are well documented but there are significant challenges not only to the operating surgeon but also to the person who holds laparoscope.[15,16,17,18,19,20] In laparoscopic surgery, the operating surgeon does not have direct visual control of the operative field. The surgeon depends on the camera assistant to makeover the camera for optimum visualization of laparoscopic target of dissection. In only advanced units and hospital the laparoscopic team can afford to use an experienced camera assistant. Elsewhere this is not economically feasible on a regular basis. The purpose of non-human motorized camera holders is to facilitate camera-control to the surgeon and to stabilize the visual field during minimally invasive procedures. Recently many such, active and passive camera holders have been developed everywhere in the world to offer the surgeon an alternative and better tool for control of the operating surgeon. The advantages of non-human camera operator include[2,19]: • Elimination of the fatigue of the assistant who holds the camera. • Elimination of fine motor tremor and little inaccurate movements.. • Delivery of a steady and tremor-free image. • Non-dependency on camera operator. • Reduced cost of surgery. • Reduced number of highly skilled staff. II.LITERATURE REVIEW Robotic–assisted surgery is a new trend in medicine, which aims to help the surgeon by taking advantage of robots’ high accuracy and accessibility[1]. Introducing a robotic assistant as an integral part of the surgical tool array provides the surgeon with several advantages. These advantages include off-loading of the routine tasks and reduction of the number of human assistants in the operating room. In addition, by using the capabilities of the robot, the surgeon can complement his own skills with the accuracy, motion steadiness, and repeatability of the robot[10]. The experimental comparison, presented in journal by Kavoussi, et al., 1996,[3] compared the K. Kishore Kumar et al. / International Journal of Engineering and Technology (IJET) ISSN : 0975-4024 Vol 7 No 1 Feb-Mar 2015 294 performance of a human assistant and a robotic assistant in manipulating a laparoscope. The results of this comparison emphasized the superiority of the robot in terms of motion steadiness. Another work by Kazanzides, et al., 1995,[4] presented experimental results comparing the cross sections of a manually broached implant cavities and cross sections of robot milled cavities for hip replacement surgery. The comparison resulted in clear prominence of the robot in performing accurate milling of the implant cavities. Noticing these features of the robot, several researchers invested efforts in assimilating the robot in the surgical arena[12,13,14]. Another journal by Dr.R.K.Mishra compared PMAT camera holder with traditional assistant driven laproscopic camera control for laproscopic appedicectomy and ovarian cystectomy had given good practical results[1].six Possible laproscopic basic moments required are given as up,down, in ,out,to the left and to the right indicated in fig2.2,fig2.3 Fig:2.1(FROM[1]) Fig:2.2 Fig: 2.3 The following pictures fig:2.1 PMAT Camera holderare developed by DR.R.K.Mishra ,laproscopic surgeon ,laproscopic hospital,new delhi,india for the purpose of camera manipulation[1] Fig:2.2 camera moment Right to left, Fig:2.3 moment in and out III. PARALLEL AND SERIAL MANIPULATOR From the two robot architectures, i.e., the serial and parallel ones, the one most compliant with the fundamental requirements is the parallel architecture. In contrast with the bulky serial architecture, the compact and lightweight parallel architectures simplify the relocation of the robot in the operating room, save necessary space, and allow easy sterilization by covering the robot with a closed drape. The relatively small work volume of the parallel robots, if correctly designed, can introduce an important safety feature. In addition, parallel robots behave safely near singularity. When the robot traces a path towards a singular configuration, the required forces from the actuators reach high values. Consequently, monitoring the electrical current of the actuator motors gives a reliable warning against approaching singular configurations. In serial robots, singular configurations are associated with very high values of joint velocities and this introduces a hazardous element.FIG3.1 parallel robot for spinal surgery Fig. 3.1. .The MARS/Spine Assist robot for spinal surgery (courtesy of Mazor Surgical Technologies) The parallel robots provide accuracy with lower price when compared to similar serial robots with the same accuracy level. Some accuracy levels may not be achieved with serial robots. These high levels of accuracy are important for eye surgery Based on the above arguments, we may conclude that the parallel architecture is better than the serial one for medical applications which requires minimum workspace . Robots are slowly entering the medical field with systems such as the DaVinci (Intuitive Surgical) , Zeus (Computer Motion) robots. Parallel structures also play a role in this evolution. For example in the Crigos system of Brandt [24], a parallel robot was used for orthopedic surgery operations, while the INRIA active wrist has been successfully employed K. Kishore Kumar et al. / International Journal of Engineering and Technology (IJET) ISSN : 0975-4024 Vol 7 No 1 Feb-Mar 2015 295 for ophthalmological surgery operations on dogs [23]. In the SurgiScope system provided by ISIS Robotics ISIS, a Delta type robot is used as a microscope stand Another example addresses one difficulty for surgical robot which is to follow the patient’s motion. This has motivated the development of the MARS robot which has a 6-UPS structure [25]; the robot is directly mounted on the patient’s bony structure near the surgical site. This robot has been used as a surgical tool guiding spinal pedicle screws placement( figure 3.1). and is sold by Mazor , MAZ as the Spine Assist robot IV. MODELLING OF 4 ARM PARALLEL MANIPULATOR USING SOLID WORKS The four arm parallel manipulator consists of fixed plate/base plate and a movable plate that which are connected with drive and driven links that help to move the lower plate to a required area.[5] ,[6].when compared to delta parallel robot top plate/fixed plate is a octoganal shape it is not a triangular/circular shape and bottom plate was also varied when compared to delta parallel robot .A four arm parallel manipulator has four motors that attach to four individual driver links; these driver links then attach to four separate arms. These arms tend to be attached by ball joints or ball-and-socket joints at both ends of the driver link, meaning that for every motor there is one driver link and for every driver link there are 2 links that make up one arm.[7] The arms are then connected to the end effecter. thus, the end effector is connected to eight links but only four arms.The key difference with the Delta robot is the use of four kinematic chains instead of three The basic concept of 4 arm Parallel manipulator is described by a simple architectural scheme as illustrated in Fig. 4.1,where joints are represented by lines . The manipulator is based on four independent chains between the base and the End-Effector (EE). Let R,and S represent revolute,and sperical joints, respectively,FIG4.2Assembeled Parallel manipulator,FIG:4.3Indication of link lenths (L1&L2)and R1 and R2,TABLE:4.1A Dimentions Fig :4.1, Architectural scheme of parallel manipulator Fig:4.2.parallel manipulator K. Kishore Kumar et al. / International Journal of Engineering and Technology (IJET) ISSN : 0975-4024 Vol 7 No 1 Feb-Mar 2015 296
منابع مشابه
Kinematic and Dynamic Analysis of Tripteron, an Over-constrained 3-DOF Translational Parallel Manipulator, Through Newton-Euler Approach
In this research, as the main contribution, a comprehensive study is carried out on the mathematical modeling and analysis of the inverse kinematics and dynamics of an over-constraint three translational degree-of-freedom parallel manipulator. Due to the inconsistency between the number of equations and unknowns, the problem of obtaining the constraint forces and torques of an over-constraint m...
متن کامل3-RPS Parallel Manipulator Dynamical Modelling and Control Based on SMC and FL Methods
In this paper, a dynamical model-based SMC (Sliding Mode Control) is proposed fortrajectory tracking of a 3-RPS (Revolute, Prismatic, Spherical) parallel manipulator. With ignoring smallinertial effects of all legs and joints compared with those of the end-effector of 3-RPS, the dynamical model ofthe manipulator is developed based on Lagrange method. By removing the unknown Lagrange multipliers...
متن کاملAn Efficient Algorithm for Workspace Generation of Delta Robot
Dimensional synthesis of a parallel robot may be the initial stage of its design process, which is usually carried out based on a required workspace. Since optimization of the links lengths of the robot for the workspace is usually done, the workspace computation process must be run numerous times. Hence, importance of the efficiency of the algorithm and the CPU time of the workspace computatio...
متن کاملKinematic Synthesis of Parallel Manipulator via Neural Network Approach
In this research, Artificial Neural Networks (ANNs) have been used as a powerful tool to solve the inverse kinematic equations of a parallel robot. For this purpose, we have developed the kinematic equations of a Tricept parallel kinematic mechanism with two rotational and one translational degrees of freedom (DoF). Using the analytical method, the inverse kinematic equations are solved for spe...
متن کاملInterval Analysis of Controllable Workspace for Cable Robots
Workspace analysis is one of the most important issues in the robotic parallel manipulator design. However, the unidirectional constraint imposed by cables causes this analysis more challenging in the cabledriven redundant parallel manipulators. Controllable workspace is one of the general workspace in the cabledriven redundant parallel manipulators due to the dependency on geometry parameter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015