In vivo comparison of 2D and 3D T2* in the rat lung using hyperpolarized helium-3 MRI at 1.5 T
نویسندگان
چکیده
The transverse relaxation time, T2, of hyperpolarized helium-3 in the lungs is a measure of the MR signal duration and it is an important parameter for pulse sequence optimization and image contrast. The T2 has also shown promise in characterizing lung microstructure due to its sensitivity to local gradients caused by gas-tissue interfaces, whose abundance per unit volume changes with lung inflation and pathological modification [1,2,3]. Despite the lung’s three-dimensional, folded, extensible structure, most measurements of helium-3 T2 have been performed using 2D projection imaging which inherently neglects the effects of the complex microstructure on T2. This work uses five rats in vivo to compare the T2 in a 2D projection image with true 3D imaging with 3, 6, and 12 slices.
منابع مشابه
The Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose
Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...
متن کاملI-45: Advance MRI Sequences in Pelvic Endometriosis
Background: To assess MRI in diagnosing endometriotic lesions, emphasizing T2*weighted imaging efficacy. Materials and Methods: This prospective study of 48 females (22-38 years, average 29.6) clinically suspected of endometriosis from September 2009 to April 2012. MRI was performed with a 1.5 T imager (Siemens) with a body array coil. T1, T2 and T2* weighted (2D-FLASH) sequences were obtained ...
متن کاملExternal radiotherapy of intact breast: A comparison between 2D (single CT- slice) and 3D (full CT-slices) plans
Background: Tangential irradiation of intact breast is one of the most common procedures performed in any radiotherapy center. This method is performed by using 2D and 3D treatment planning. The aim of this study was to compare 2D with 3D plans in breast conserving radiotherapy. Homogeneity of isodose, and lung received dose were compared. Materials and Methods: Twenty patients with br...
متن کاملAssessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification
Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...
متن کاملIology Contribution Proton and Hyperpolarized Helium Magnetic Resonance Imaging of Radiation-induced Lung Injury in Rats
Purpose: To assess the usefulness of hyperpolarized helium (He) MRI, including apparent diffusion coefficient measurements, in the detection and evaluation of radiation-induced lung injury in rats. Methods and Materials: Female Fischer-344 rats were treated to the right lung with fractionated dose of 40 Gy (5 8 Gy) using 4-MV photons. Conventional proton (H) and hyperpolarized (He) MRI were use...