Simple disposable method for quantitative cultures of urine.
نویسنده
چکیده
A disposable kit was tested as a means of detecting significant bacteriuria by quantitative culture of urine. The total error in 3,563 specimens tested by five investigators was less than 1%. The method was very effective in differentiating significant bacteriuria, i.e., more than 100,000 bacteria per ml of urine from uninfected urine. In specimens from patients with urinary tract abnormalities who had mixed bacterial flora, the absolute numbers obtained with the dip-inoculum method had a 10% variation when compared to results obtained by calibrated loop or dilution pour plate methods. Therefore, the main utility of the kit is for screening and following patients after therapy. A significant delay in time between inoculation of the medium in the kit with the freshly voided urine and incubation of the kit to promote growth did not affect the reliability of the kit as a method of doing quantitative urine cultures to detect bacteriuria.
منابع مشابه
Development of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design
In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...
متن کاملA simple quantitative and qualitative microbiological screening test for bacteriuria.
A simple, accurate screening test for significant bacteriuria is described. It entails brief contact of a freshly voided specimen of urine with the surface of a solid culture medium lining the wall of a transparent disposable plastic container, incubating it at 37 degrees C for 24 hours, and counting colonies developing on a proscribed surface area. The method obviates errors due to contaminant...
متن کاملCOMPARATIVE EVALUATION OF QUANTITATIVE PROTEIN MEASUREMENTS IN 8-12 AND 24 HOUR URINE SAMPLES FOR DIAGNOSIS OF PRE-ECLAMPSIA
ABSTRACT Background: In this study our purpose was to determine whether 8 and/or 12 hour urine total protein values correlate with the 24 hour value to confirm the diagnosis of pre-eclampsia. Methods: The study population included 70 inpatients with hypertensive disorders of pregnancy. Patient's urine was collected over 24 hours with the first 8 hours, next 4 hours, and remaining 12 hours in s...
متن کاملDisposable microfluidic device with ultraviolet detection for highly resolved screening of illicit drugs.
A disposable microfluidic device was constructed by conveniently integrating one poly(methyl methacrylate) board with four reservoirs and one fractured fused-silica capillary with 50 microm i.d. and 7.5 cm total length on a printed circuit board for applying sampling and separation voltages. The disposable microfluidic device combined with a home-made ultraviolet workstation could be convenient...
متن کاملSimple and convenient method for culturing anaerobic bacteria.
A simple and convenient method for culturing anaerobic bacteria is described. Cultures can be grown in commercially available flasks normally used for preparation of sterile external solutions. A special disposable rubber flask closure maintains anaerobic conditions in the flask after autoclaving. Growth of a variety of anaerobic oral bacteria was comparable to that obtained after anaerobic inc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied microbiology
دوره 19 3 شماره
صفحات -
تاریخ انتشار 1970