Safety and biocompatibility of a novel self-expanding nitinol carotid stent with hybrid cell design in a porcine model of neointimal hyperplasia.
نویسندگان
چکیده
BACKGROUND Stent design may influence the outcomes, suggesting that adverse event rates vary according to free cell area and cell design. Open cell design technology of self-expandable stents, dedicated for carotid revascularisation has better deliverability, although closed cell technology is expected to cause fewer thromboembolic events. AIM To evaluate the feasibility and vascular response of novel, hybrid cell, self-expandable nitinol stents (MER®, Balton, Poland) implanted into porcine carotid arteries. Hybrid cell design combines open and closed cell technology. METHODS All tested stents were implanted with 10% overstretch into 10 carotid segments of Polish domestic pigs. Control angiography was obtained immediately before and after vascular interventions as well as 28 days after the procedure. Thereafter, animals were sacrificed, and the treated segments were harvested and evaluated in the independent histopathology laboratory. RESULTS All stents were easily introduced and implanted, showing good angiographic acute outcome. At 28 days, in the angiography, all vessels were patent with no signs of thrombi or excessive neointimal formation, with the late lumen loss of -0.11 ± 0.3 mm and percentage diameter stenosis 10.18 ± 8.1%. There was a 10% increase in the vessel reference diameter when compared to baseline (4.57 ± 0.5 vs. 4.96 ± 0.3 mm, p < 0.01). In the histopathology, mean area stenosis was 17.4% and mean intimal thickness was 0.20 mm. At histopathology, the mean injury, inflammation, and fibrin scores were low. Endothelialisation was complete in all stents, and neointimal tissue appeared moderately mature as shown by the moderate mean neointimal smooth muscle score. Nonetheless, histopathology shows one stent affected by peri-strut granulomas and one stent affected by marked mineralisation. CONCLUSIONS The novel Polish self-expandable nitinol carotid stent with hybrid cell technology shows optimal biocompatibility and a vascular healing profile, and therefore may be introduced for first-in-man application.
منابع مشابه
Oversizing of self-expanding stents: influence on the development of neointimal hyperplasia of the carotid artery in a canine model.
BACKGROUND AND PURPOSE In carotid artery stent placement, marked oversizing of the stent relative to the internal carotid artery lumen is common. This study was performed to determine the influence of using oversized self-expanding nitinol stents on neointimal hyperplasia. METHODS In six greyhound dogs, 24 self-expanding nitinol stents (eight SMART stents, eight Easy Wallstents, eight Sinus-F...
متن کاملComparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model.
OBJECTIVE Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent c...
متن کاملSelf-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model.
PURPOSE To assess the efficacy of metal stents for the treatment of different forms and sizes of carotid aneurysms. METHODS A total of 14 experimentally constructed aneurysms in dogs were treated with transfemorally placed balloon-expandable tantalum and self-expanding nitinol stents. RESULTS In 10 cases, stenting produced either immediate complete occlusion of the aneurysm (n = 7) or compl...
متن کاملNovel A20-gene-eluting stent inhibits carotid artery restenosis in a porcine model
BACKGROUND Carotid artery stenosis is a major risk factor for ischemic stroke. Although carotid angioplasty and stenting using an embolic protection device has been introduced as a less invasive carotid revascularization approach, in-stent restenosis limits its long-term efficacy and safety. The objective of this study was to test the anti-restenosis effects of local stent-mediated delivery of ...
متن کاملPrevention of carotid artery restenosis after sirolimus-coated stent implantation in pigs.
BACKGROUND AND PURPOSE To test the feasibility of self-expanding drug-coated nitinol stents for prevention of restenosis in an animal model. Stent implantation in the carotid artery (CA) has been shown to be feasible for treatment of CA stenosis. Even though the restenosis rate in CA is reported to be lower than in the coronary and peripheral arteries, problems may arise with increasing numbers...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Kardiologia polska
دوره 73 4 شماره
صفحات -
تاریخ انتشار 2015