Significance of background optical properties, time-resolved information and optode arrangement in diffuse optical imaging of term neonates.

نویسندگان

  • J Heiskala
  • P Hiltunen
  • I Nissilä
چکیده

The significance of accurate knowledge of background optical properties and time-resolved information in reconstructing images of hemodynamic changes in the neonatal brain from diffuse optical imaging data was studied using Monte Carlo (MC) simulation. A segmented anatomical magnetic resonance (MR) image and literature-derived optical properties for each tissue type were used to create a voxel-based anatomical model. Small absorbing perturbations were introduced into the anatomical model to simulate localized hemodynamic responses related to brain activation. Perturbation MC (pMC) was used as the primary method of image reconstruction. For comparison, reconstructions were also performed using the finite element method (FEM) to solve the diffusion approximation (DA) to the radiative transfer equation (RTE). The effect of optode layout was investigated using three different grids. Of the factors studied, the density of the optode grid was found to have the greatest effect on image quality. The use of time-resolved information significantly improved the spatial accuracy with all optode grids. Adequate knowledge and modeling of the optical properties of the background was found to significantly improve the spatial accuracy of the reconstructed images and make the recovery of contrast of absorption changes more consistent over simplified modeling. Localization accuracy of small perturbations was found to be 2-3 mm with accurate a priori knowledge of the background optical properties, when a grid with high optode density (>1 optode cm(-2)) was used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of image artifacts induced by change in the optode coupling in time-resolved diffuse optical tomography.

Tomographic images of the optical properties can be reconstructed using inversion algorithms for diffuse optical tomography (DOT); however, changes in the optode coupling that occurs while obtaining an object's measurements may often lead to the presence of artifacts in the reconstructed images. To reduce the number of artifacts induced by optode coupling, previous studies have introduced (unkn...

متن کامل

Optode positional calibration in diffuse optical tomography.

Although diffuse optical tomography is a highly promising technique used to noninvasively image blood volume and oxygenation, the reconstructed data are sensitive to systemic difference between the forward model and the actual experimental conditions. In particular, small changes in optode location or in the optode-tissue coupling coefficient significantly degrade the quality of the reconstruct...

متن کامل

Design novel optical sensor for determination of bismuth based on immobilization of 4-(4-nitrophenyl)-1-naphthol on a triacetylcellulose membrane

A novel optical sensor has been proposed for sensitive determination of bismuth ion basedon immobilization of 4-(4-nitrophenylazo)-1-naphthol on a triacetylcellulose membrane.Chemical binding of bismuth ions in solution with a 4-(4-nitrophenylazo)-1-naphtholimmobilized on the triacetylcelluse surface could be monitored spectrophotometrically. Theoptode shows excellent response over wide concent...

متن کامل

Optimization of optode arrangements for diffuse optical tomography: A singular-value analysis.

We develope a method to optimize the resolution of diffuse optical tomographic instruments. Singular-value analysis of the tomographic weight matrix associated with specific data types, geometries, and optode arrangements is shown to provide a measure of image resolution. We achieve optimization of device configuration by monitoring the resolution measure described. We introduce this idea and d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2009