Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer
نویسندگان
چکیده
To investigate the potential relationship between perfusion parameters from first-pass dual-input perfusion computed tomography (DI-PCT) and iodine uptake levels estimated from dual-energy CT (DE-CT).The pre-experimental part of this study included a dynamic DE-CT protocol in 15 patients to evaluate peak arterial enhancement of lung cancer based on time-attenuation curves, and the scan time of DE-CT was determined. In the prospective part of the study, 28 lung cancer patients underwent whole-volume perfusion CT and single-source DE-CT using 320-row CT. Pulmonary flow (PF, mL/min/100 mL), aortic flow (AF, mL/min/100 mL), and a perfusion index (PI = PF/[PF + AF]) were automatically generated by in-house commercial software using the dual-input maximum slope method for DI-PCT. For the dual-energy CT data, iodine uptake was estimated by the difference (λ) and the slope (λHU). λ was defined as the difference of CT values between 40 and 70 KeV monochromatic images in lung lesions. λHU was calculated by the following equation: λHU = |λ/(70 - 40)|. The DI-PCT and DE-CT parameters were analyzed by Pearson/Spearman correlation analysis, respectively.All subjects were pathologically proved as lung cancer patients (including 16 squamous cell carcinoma, 8 adenocarcinoma, and 4 small cell lung cancer) by surgery or CT-guided biopsy. Interobserver reproducibility in DI-PCT (PF, AF, PI) and DE-CT (λ, λHU) were relatively good to excellent (intraclass correlation coefficient [ICC]Inter = 0.8726-0.9255, ICCInter = 0.8179-0.8842; ICCInter = 0.8881-0.9177, ICCInter = 0.9820-0.9970, ICCInter = 0.9780-0.9971, respectively). Correlation coefficient between λ and AF, and PF were as follows: 0.589 (P < .01) and 0.383 (P < .05). Correlation coefficient between λHU and AF, and PF were as follows: 0.564 (P < .01) and 0.388 (P < .05).Both the single-source DE-CT and dual-input CT perfusion analysis method can be applied to assess blood supply of lung cancer patients. Preliminary results demonstrated that the iodine uptake relevant parameters derived from DE-CT significantly correlated with perfusion parameters derived from DI-PCT.
منابع مشابه
Dual- Energy CT (DECT) Pulmonary Angiography in Acute Pulmonary Thromboembolism (PTE): Causes, Semiology and Potential Diagnostic Pitfalls
Citation: Gálvez García S, Muñoz Ruíz AL, Nava Tomás E, Chung H, Prieto Fernández A (2016) DualEnergy CT (DECT) Pulmonary Angiography in Acute Pulmonary Thromboembolism (PTE): Causes, Semiology and Potential Diagnostic Pitfalls. J Adv Radiol Med Image 1(2): 204. doi: 10.15744/24565504.1.204 Volume 1 | Issue 2 Journal of Advances in Radiology and Medical Imaging Learning Objectives The dual-ener...
متن کاملCovid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT
A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...
متن کاملQuantification of Lung Perfusion Blood Volume by Dual-Energy CT in Patients With and Without Chronic Obstructive Pulmonary Disease
The introduction of a dual-source CT system in the same gantry resolved many of the technical issues that previously limited the application of dual-energy CT pulmonary angiography. Dual-energy CT pulmonary angiography does not expose patients to any significant additional radiation beyond that of standard CT pulmonary angiography [1, 2]. Post-processing software is then used to subtract 80-kV ...
متن کاملDual Energy CT Imaging for Suspected Pulmonary Embolism Using a Lower Dose of Contrast Agent
CT is the preferred imaging modality to diagnose pulmonary embolism Evaluation of pulmonary embolism with dual energy CT (DECT) retains diagnostic accuracy using less contrast material than standard CT Virtual monochromatic images, derived from DECT data, show contrast material at greater intensity than standard CT Iodine images show the distribution of contrast material and can be used to asse...
متن کاملDual-Energy Micro-CT Functional Imaging of Primary Lung Cancer in Mice Using Gold and Iodine Nanoparticle Contrast Agents: A Validation Study
PURPOSE To provide additional functional information for tumor characterization, we investigated the use of dual-energy computed tomography for imaging murine lung tumors. Tumor blood volume and vascular permeability were quantified using gold and iodine nanoparticles. This approach was compared with a single contrast agent/single-energy CT method. Ex vivo validation studies were performed to d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 96 شماره
صفحات -
تاریخ انتشار 2017